If the self-test button is released within the next 5 seconds, the next text will be
printed:
SERIAL PORT SAVED AT ... 19200 BAUD
Otherwise, if the self-test button is still pressed after the 5 seconds, the EPC1100 will
print the text corresponding to the next allowed baud rate:
Release the button to 9600 BAUD
The process will go on in the same way, printing the texts
Release the button to 4800 BAUD
Release the button to 2400 BAUD
cyclically, until the self-test button is released after one of them.
After programming the serial baud rate, the EPC1100 must be reseted in order to set
the new values. The EPC1100 can be reseted in two ways:
•
SOFTWARE: Reset command – ESC @.
•
HARDWARE: Switch the EPC1100 OFF and then switch it ON.
3.2.2- HEXADECIMAL MODE
Immediately after baud rate is programmed, EPC1100 will print the text:
~~~~~~~HEXADECIMAL MODE~~~~~~~~~
Press the button for enter in
HEXADECIMAL MODE .................................
If the self-test button is pressed within the next 5 seconds, the next text will be printed:
---HEXADECIMAL MODE ACTIVATED---
reporting that EPC1100 is in hexadecimal mode. In any other case, EPC1100 is in
normal mode, waiting for some command or data.
When the hexadecimal mode is activated, all data received is printed in hexadecimal
code (no command is performed). Through this function, user can simply confirm
whether or not the data sent from the host device is correctly received or if some
incorrect data has been sent from the host device.