FEMA ELECTRÓNICA . SERIES M . M60-LC
11
Press ‘SQ’ (
<
) for 1 second to access the ‘
con
-
figuration menu
’. For a description on how to op
-
erate inside the menus see section
. For a
full vision of the ‘
configuration menu
’ structure
see section
.
At the initial set up of the instrument, first configure the
theoretical part of the load cell at the ‘
Load cell param-
eters’
(‘
cELL
’)
menu and later configure the empirical part of
the load cell at the ‘
Field correction
’ (‘
F.cor
’) menu.
See sec-
for additional information.
•
at the ‘
Decimal point
’ (‘
dP
’) parameter,
select the deci-
mal point position. Move the decimal point with key ‘LE’
(
3
). The position defined will be used for all reading pa
-
rameters.
Example :
to read in ‘Kg’ with tenths of kilograms, place the
decimal point at ‘XXXXX.X’ and the reading will be always
be shown with 1 decimal.
Changing the position of the decimal point will only light a
different decimal point led, but will not modify or re-scale
the measure of the instrument.
•
at the ‘
Sensitivity mV/V
’ (‘
MV.V
’) parameter, configure the
value for the load cell sensitivity. Accepts any value between
0.0001 and 99.9999 mV/V. Default value is 2.0000 mV/V.
•
at the ‘
Nominal weight
’ (‘
LoAd
’) parameter, configure the
nominal weight of the load cell. accepts any value between
0 and 999999. The decimal point will be shown in the posi
-
tion configured at the ‘
Decimal point
’ (‘
dP
’) parameter. De
-
fault value is 1000.
Example : for a 5 Kg cell, configure a value of 5000 to read
in grams.
•
at the ‘
Excitation voltage
’ (‘
V.Exc
’) parameter, configure
the voltage to power the load cell. Select ‘5 Vdc’ or ‘10 Vdc’.
Default value is 10 Vdc. Select ‘LAb’ for a millivolt meter
mode in laboratory
The ‘
Field correction
’ (‘
F.cor
’) menu includes the functions for
the empirical configuration of the load cell. See section
for additional information on each function.
•
at the ‘
Low weight correction
’ (‘
F.Lo
’) parameter, intro
-
duce the real value of the actual weight at the cell. Use the
lowest weight possible, close to 0. Press key SQ (‘
<
’) to
start the correction process.
•
at the ‘
High weight correction
’ (‘
F.hI
’) introduce the real
value of the actual weight at the cell. Use the lowest weight
possible, close to nominal weight of the cell. Press key SQ
(‘
<
’) to start the correction process.
The ‘
System zero
’ (‘
S.ZEr
’) entry assigns the actual weight to
the ‘system zero’ of the instrument. See section
for ad-
ditional information.
1.12.3 Initial setup menu
Load cell
parameters
Initial
configuration
Deci
mal point
Sensitivity
mV/V
Nominal weight
Excitation
voltage
5 Vdc
10 Vdc
Field
correction
High weight
correction
Low weight
correction
Low weight
value
High weight
value
System zero
Laboratory
mode