2

SIGNAL CONVERTER 

I4P

Signal converter for process and temperature signals, isolated, industrial applications

Isolated signal converter for process and temperature signals. Accepts a wide range of process signals including 4/20 mA, 0/10 Vdc, potentiometers 

and resistance measurements, providing excitation voltage to power the transducer when needed. Accepts a wide range of temperature signals, 

including Pt100, Pt500, Pt1000, thermocouples J, K, N, E, T, R, S, C and B, NTC sensors from 44004 to 44008 and from 44030 to 44034, and a 

configurable NTC range with configurable R

25

 and ß parameters.

Configurable output in 4/20 mA (active or passive) or 0/10 Vdc. Universal power supply from 18 to 265 Vac/dc. 3 way isolation between input, output 

and power circuits. Circuit isolation prevents ground loops and transient propagation, protecting remote equipment and signal integrity. 

Predefined configuration codes available for fast and easy configuration. 

Advanced configuration menu available to customize input and output 

signal  ranges  to  specific  values  required.  Configuration  through 

front  push-button  keypad.  Front  information  displays  available  for 

configuration and system information (input signal value, output signal 

value, configured label, signal percentage and process value). 
Built-in  ‘

force

’  functions  to  manually  generate  low  and  high  output 

signals,  to  validate  remote  instrumentation  during  installation.  ‘

SOS

’ 

mode to help on critical maintenance and repairs. Configurable power 

frequency  rejection  filter.  ‘

Password

’  function  to  block  non-authorized 

access to ‘

configuration menu

’.

Designed for industrial use, with potential integration into a wide range of 

applications, reduced cost, excellent quality and available customization.

1. 

 How to order

1.  How to order

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 2

2.  Material included

  . . . . . . . . . . . . . . . . . . . . . . 2

3.  Additional information

. . . . . . . . . . . . . . . . . . . . 2

4.  Installation and start-up

. . . . . . . . . . . . . . . . . . . 3

5. Typical applications  . . . . . . . . . . . . . . . . . . . . . 3
6. SOS mode  . . . . . . . . . . . . . . . . . . . . . . . . . . 3
7. Messages  . . . . . . . . . . . . . . . . . . . . . . . . . . 3

8.  Predefined configuration codes

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 4

9.  Connections and dimensions (mm (

inch

)) . . . . . . . . . . 5

10. How to operate the instrument

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 6

10.1 Configuration system 

6

10.2  ‘Normal mode’ of operation 

6

10.3  How to operate the ‘Configuration menu’ 

6

10.4 How to operate the ‘Force’ menu 

7

10.5 How to activate the ‘Messages’ function 

7

10.6 Fast and advanced configurations 

7

11. Input signals  . . . . . . . . . . . . . . . . . . . . . . . . 8

11.1 Process 

8

11.2  Potentiometers 

8

11.3  Resistances 

9

11.4  NTC sensors 

9

11.5 Thermocouples 

10

11.6  Pt100 sensors and other Pt 

11

12.  Technical specifications

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 13

13. Configuration menu

. . . . . . . . . . . . . . . . . . . . 14

13.1 Function codes 

14

13.2 Input range 

14

13.3 Output range 

15

13.4 Temperature configuration 

16

13.5 Process configuration 

16

13.6 Advanced scaling 

18

13.7 Display information 

19

13.8 Key ‘UP’ (‘force’ menu) 

19

13.9 Key ‘LE’ (‘messages’ function) 

20

13.10 ‘Tools’ menu 

20

14. Full configuration menu

. . . . . . . . . . . . . . . . . . 22

15.  Factory default parameters

. . . . . . . . . . . . . . . . 24

16.  Error codes

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 24

17.  Precautions on installation

. . . . . . . . . . . . . . . . 25

18.  Warranty

  . . . . . . . . . . . . . . . . . . . . . . . . . 25

19.  CE declaration of conformity

. . . . . . . . . . . . . . . 25

INDEX

USER’S MANUAL

The instrument is provided with the following elements:

• 1 x instrument 

I4P

• 4 x plug-in screw terminals
• 1 x quick installation guide

2. 

 Material included

User’s Manual

www.fema.es/docs/5488_I4P_manual_en.pdf

Datasheet

www.fema.es/docs/5486_I4P_datasheet_en.pdf

Quick installation guide

www.fema.es/docs/5484_I4P_installation_en.pdf

CE declaration

www.fema.es/docs/5480_CE-Declaration_I4P_en.pdf

Warranty

www.fema.es/docs/4153_Warranty1_en.pdf

Web

www.fema.es/Series_I4

3. 

 Additional information

When  the  marks  ‘

Attention

’  or  ‘

Risk  of  electrical  shock

’ 

appear, read the documentation for information about the 

nature of the risk.

Reference

Description

I4P

Signal converter

I4P.1442

Signal converter with custom features

Summary of Contents for I4 Series

Page 1: ...www fema es SERIES I4 Model I4P USER S MANUAL ISOLATED SIGNAL CONVERTER Section INDUSTRIAL 5488r02 Process mA Vdc NTC Temperature tc Temperature Pt Temperature Potentiometer Resistances INDUSTRIAL...

Page 2: ...t quality and available customization 1 How to order 1 How to order 2 2 Material included 2 3 Additional information 2 4 Installation and start up 3 5 Typical applications 3 6 SOS mode 3 7 Messages 3...

Page 3: ...an easy resolution of the problem Additionally each instrument can be assigned a custom label code of up to 8 characters see Table 1 that can be displayed at the front display or at the messages sequ...

Page 4: ...gnals see section 13 6 Notes Code uSEr indicates that a user custom configuration is active and it does not match any of the listed codes This code is non selectable for information only Example selec...

Page 5: ...ctive output mA in mA out 7 8 9 mA mA 4 20mA passive output external loop power needed mA out mA in 7 8 9 mA mA 0 10Vdc common Vdc 7 8 9 common Vdc fuse Pt Ntc resistance thermocouple Pt 3rd wire ther...

Page 6: ...tion HOW TO OPERATE INSIDE THE CONFIGURATION MENU Inside the configuration menu use the front keypad to move through menu entries parameters and select configuration values Key SQ functions as the ENT...

Page 7: ...force menu press the LE 3 key or press the key UP 5 key until the parameter appears and select by pressing the SQ key or wait without pressing any key until the automatic rollback activates 10 4 How t...

Page 8: ...ASURING POTENTIOMETERS The instrument can be configured to measure potentiometer signals 3 wires from potentiometers with nominal value between 250Ohms and 15KOhms See connections at Table 10 The inst...

Page 9: ...of NTC can read signals down to 0Ohms and up to 16MOhms PREDEFINED CONFIGURATION CODES See Table 16 for a list of predefined input output configuration codes To activate a code see section 13 1 CUSTO...

Page 10: ...Total error Thermoc R 059 159 50 1768 C 58 3214 F 0 15 FS 2 C 060 160 0 1600 C 32 2912 F 0 15 FS 2 C 061 161 0 1000 C 32 1832 F 0 15 FS 2 C Table 24 Temperature ranges for thermocouple S Input signal...

Page 11: ...ctivate an alpha value of 0 0390 see section 13 4 This parameter is associated to the sensor and depends on the sensor manufacturer CURRENT THROUGH THE SENSOR The instrument generates 960uA through Pt...

Page 12: ...FEMA MANUFACTURING FOR INDUSTRIAL AUTOMATION 12 T h i s p a g e b l a n k...

Page 13: ...4 20mA passive max 30Vdc on terminals voltage output 0 10Vdc max 11Vdc min 0 05Vdc typ minimum load 10KOhm CONFIGURATION SYSTEM key pad display accessible at the front of the instrument configuration...

Page 14: ...or 4 20mA or 010 for 0 10Vdc signal input At the Thermocouples tc parameter select from the available thermocouples J K N E T R S C or B At the Pt sensors Pt parameter select from the available pt sen...

Page 15: ...Ntc R25 Ntc Potentiometer signal Ntc 44030 Ntc 44031 Ntc 44032 Ntc 44034 Ntc 44033 Input signal ranges are also accessible as predefined configuration codes see section 8 The predefined configuration...

Page 16: ...nfiguration Temperature units Degrees celsius Degrees fahrenheit Offset Offset in degrees Cold junction Pt alpha Process configuration Field correction low ok flashes while field correction is being a...

Page 17: ...s expressed in x xxmA or x xxVdc These four parameters define the relation between the input and the output signal see Table 31 and can be modified independently to match the specific input output rel...

Page 18: ...ed at the process parameters see section 13 6 for example Proc 150 0 select Percentage Prct to read the percentage of signal where 0 is the value assigned to the input signal low parameter and 100 is...

Page 19: ...gnal to maximum value in case of input signal overrange and to underrange output signal to minimum value in case of input signal underrange 13 10 Tools menu Key LE messagesfunction Input signal value...

Page 20: ...th of the filter slows the response speed of the instrument Value 0 disables the filter at the Dead band d bnd parameter set a value between 0 0 and 100 0 This is a percentage of the input signal high...

Page 21: ...SERIES I4 Model I4P Section INDUSTRIAL ISOLATED SIGNAL CONVERTERS www fema es 21 T h i s p a g e b l a n k...

Page 22: ...on 10 For a full vision of the configuration menu structure see section 13 Function code Enter the function code see section 8 Output range Resistances 1KOhm range 100KOhm range 1MOhm range 10KOhm ran...

Page 23: ...put signal low Output signal high Process low Process high Process decimal point 0 0 to 100 0 SOS mode of output Display information Input signal value Output signal value Label Process value Key LE m...

Page 24: ...errange to 21mA 10 4Vdc to underrange to 3mA or 0 05Vdc or to hold value See the On error on Er parameter at section 13 10 Function code codE 10 c 010 Input range InP 4 20mA Output range out 4 20mA Te...

Page 25: ...ctrovalves together with signal and or control cables The use of shielded cables is recommended to prevent the coupling of environmental electromagnetic noise connected to earth only one cable end sid...

Page 26: ...FEMA MANUFACTURING FOR INDUSTRIAL AUTOMATION 26 Notes...

Page 27: ...SERIES I4 Model I4P Section INDUSTRIAL ISOLATED SIGNAL CONVERTERS www fema es 27 Notes...

Page 28: ......

Reviews: