 · MANUFACTURING FOR INDUSTRIAL AUTOMATION 

4

Table 2 

|

 Predefined configuration codes - Input / Output

Input Signal  

Range

Sensor

Output 4/20 mA

 

Code

Output 0/10 Vdc

 

Code

See section 

...

4/20 mA

Process

010

110

11.1

0/10

Vdc

011

111

0/100

%

Potentiometer

012

112

11.2

0/100

%

Passive Pot.

013

113

0/1 KOhm

Resistance

014

114

11.3

0/10 KOhm

015

115

0/100 KOhm

016

116

0/1 MOhm

017

117

Reserved

018 to 019

118 to 119

-80/120

ºC

Ntc 44004

020

120

11.4

-80/120

ºC

Ntc 44005

021

121

-80/120

ºC

Ntc 44006

022

122

-80/120

ºC

Ntc 44007

023

123

-80/120

ºC

Ntc 44008

024

124

-80/75

ºC

Ntc 44030

025

125

-80/75

ºC

Ntc 44031

026

126

-80/75

ºC

Ntc 44032

027

127

-80/75

ºC

Ntc 44033

028

128

-80/75

ºC

Ntc 44034

029

129

-50/90

ºC

Ntc R

25

=10K β=3500

030

130

-200/1200

ºC

Thermocouple J

031

131

11.5

0/700

ºC

032

132

0/400 ºC

033

133

0/250 ºC

034

134

0/150

ºC

035

135

-200/1372

ºC

Thermocouple K

036

136

11.5

0/1200

ºC

037

137

0/700

ºC

038

138

0/400 ºC

039

139

0/300

ºC

040

140

0/250 ºC

041

141

0/150

ºC

042

142

Reserved

043 to 044

143 to 144

-200/1300

ºC

Thermocouple N

045

145

11.5

0/1200

ºC

046

146

0/1000

ºC

047

147

Reserved

048 to 049

148 to 149

8. 

 Predefined configuration codes

Select the desired code for your application, and check the following 

sections for more information:

• for information on how to activate a code, see section 13.1
• to customize the input and output signals, see section 13.6

Notes

• Code ‘

uSEr

’ indicates that a user custom configuration is active, and it does not 

match any of the listed codes This code is non-selectable, for information only.
Example: select code ‘

011

’ for 0/10 Vdc=4/20 mA, the instrument reads code ‘

011

’. 

Later, configure the input to 0/7 Vdc=4/20 mA, this does not match a listed code, and 

the instrument reads ‘

uSEr

’. Or change the output to 0/10 Vdc=1/5 Vdc, this does not 

match a listed code, and the instrument reads ‘

uSEr

’.

•  Code  ‘

----

’  identifies  the  end  of  the  list,  it  follows  code  ‘

199

’  and  the  list 

continues with code ‘

010

’. Select ‘

----

’ to exit the list without applying changes.

Table 2 

|

 Predefined configuration codes - Input / Output

Input Signal  

Range

Sensor

Output 4/20 mA

 

Code

Output 0/10 Vdc

 

Code

See section 

...

-200/1000

ºC

Thermocouple E

050

150

11.5

0/1000

ºC

051

151

0/800 ºC

052

152

0/500 ºC

053

153

0/300

ºC

054

154

-200/400

ºC

Thermocouple T

055

155

11.5

0/400 ºC

056

156

0/300

ºC

057

157

0/200 ºC

058

158

-50/1768

ºC

Thermocouple R

059

159

11.5

0/1600

ºC

060

160

0/1000

ºC

061

161

-50/1768

ºC

Thermocouple S

062

162

11.5

0/1600

ºC

063

163

0/2320

ºC

Thermocouple C

064

164

11.5

0/1500

ºC

065

165

250/1820

ºC

Thermocouple B

066

166

11.5

Reserved

067 to 069

167 to 169

-200/850

ºC

Pt100

 

(2 and 3 wires)

070

170

11.6

0/600

ºC

071

171

0/400 ºC

072

172

0/300

ºC

073

173

0/200 ºC

074

174

0/100

ºC

075

175

-50/+50

ºC

076

176

Reserved

077 to 079

177 to 179

-200/850

ºC

Pt500

080

180

11.6

-200/850

ºC

Pt1000

081

181

Reserved

082 to 099

182 to 199

(End of list)

                                  

‘----’

(see notes below)

(Custom selection)

                                   ‘

uSEr

(see notes below)

Summary of Contents for I4 Series

Page 1: ...www fema es SERIES I4 Model I4P USER S MANUAL ISOLATED SIGNAL CONVERTER Section INDUSTRIAL 5488r02 Process mA Vdc NTC Temperature tc Temperature Pt Temperature Potentiometer Resistances INDUSTRIAL...

Page 2: ...t quality and available customization 1 How to order 1 How to order 2 2 Material included 2 3 Additional information 2 4 Installation and start up 3 5 Typical applications 3 6 SOS mode 3 7 Messages 3...

Page 3: ...an easy resolution of the problem Additionally each instrument can be assigned a custom label code of up to 8 characters see Table 1 that can be displayed at the front display or at the messages sequ...

Page 4: ...gnals see section 13 6 Notes Code uSEr indicates that a user custom configuration is active and it does not match any of the listed codes This code is non selectable for information only Example selec...

Page 5: ...ctive output mA in mA out 7 8 9 mA mA 4 20mA passive output external loop power needed mA out mA in 7 8 9 mA mA 0 10Vdc common Vdc 7 8 9 common Vdc fuse Pt Ntc resistance thermocouple Pt 3rd wire ther...

Page 6: ...tion HOW TO OPERATE INSIDE THE CONFIGURATION MENU Inside the configuration menu use the front keypad to move through menu entries parameters and select configuration values Key SQ functions as the ENT...

Page 7: ...force menu press the LE 3 key or press the key UP 5 key until the parameter appears and select by pressing the SQ key or wait without pressing any key until the automatic rollback activates 10 4 How t...

Page 8: ...ASURING POTENTIOMETERS The instrument can be configured to measure potentiometer signals 3 wires from potentiometers with nominal value between 250Ohms and 15KOhms See connections at Table 10 The inst...

Page 9: ...of NTC can read signals down to 0Ohms and up to 16MOhms PREDEFINED CONFIGURATION CODES See Table 16 for a list of predefined input output configuration codes To activate a code see section 13 1 CUSTO...

Page 10: ...Total error Thermoc R 059 159 50 1768 C 58 3214 F 0 15 FS 2 C 060 160 0 1600 C 32 2912 F 0 15 FS 2 C 061 161 0 1000 C 32 1832 F 0 15 FS 2 C Table 24 Temperature ranges for thermocouple S Input signal...

Page 11: ...ctivate an alpha value of 0 0390 see section 13 4 This parameter is associated to the sensor and depends on the sensor manufacturer CURRENT THROUGH THE SENSOR The instrument generates 960uA through Pt...

Page 12: ...FEMA MANUFACTURING FOR INDUSTRIAL AUTOMATION 12 T h i s p a g e b l a n k...

Page 13: ...4 20mA passive max 30Vdc on terminals voltage output 0 10Vdc max 11Vdc min 0 05Vdc typ minimum load 10KOhm CONFIGURATION SYSTEM key pad display accessible at the front of the instrument configuration...

Page 14: ...or 4 20mA or 010 for 0 10Vdc signal input At the Thermocouples tc parameter select from the available thermocouples J K N E T R S C or B At the Pt sensors Pt parameter select from the available pt sen...

Page 15: ...Ntc R25 Ntc Potentiometer signal Ntc 44030 Ntc 44031 Ntc 44032 Ntc 44034 Ntc 44033 Input signal ranges are also accessible as predefined configuration codes see section 8 The predefined configuration...

Page 16: ...nfiguration Temperature units Degrees celsius Degrees fahrenheit Offset Offset in degrees Cold junction Pt alpha Process configuration Field correction low ok flashes while field correction is being a...

Page 17: ...s expressed in x xxmA or x xxVdc These four parameters define the relation between the input and the output signal see Table 31 and can be modified independently to match the specific input output rel...

Page 18: ...ed at the process parameters see section 13 6 for example Proc 150 0 select Percentage Prct to read the percentage of signal where 0 is the value assigned to the input signal low parameter and 100 is...

Page 19: ...gnal to maximum value in case of input signal overrange and to underrange output signal to minimum value in case of input signal underrange 13 10 Tools menu Key LE messagesfunction Input signal value...

Page 20: ...th of the filter slows the response speed of the instrument Value 0 disables the filter at the Dead band d bnd parameter set a value between 0 0 and 100 0 This is a percentage of the input signal high...

Page 21: ...SERIES I4 Model I4P Section INDUSTRIAL ISOLATED SIGNAL CONVERTERS www fema es 21 T h i s p a g e b l a n k...

Page 22: ...on 10 For a full vision of the configuration menu structure see section 13 Function code Enter the function code see section 8 Output range Resistances 1KOhm range 100KOhm range 1MOhm range 10KOhm ran...

Page 23: ...put signal low Output signal high Process low Process high Process decimal point 0 0 to 100 0 SOS mode of output Display information Input signal value Output signal value Label Process value Key LE m...

Page 24: ...errange to 21mA 10 4Vdc to underrange to 3mA or 0 05Vdc or to hold value See the On error on Er parameter at section 13 10 Function code codE 10 c 010 Input range InP 4 20mA Output range out 4 20mA Te...

Page 25: ...ctrovalves together with signal and or control cables The use of shielded cables is recommended to prevent the coupling of environmental electromagnetic noise connected to earth only one cable end sid...

Page 26: ...FEMA MANUFACTURING FOR INDUSTRIAL AUTOMATION 26 Notes...

Page 27: ...SERIES I4 Model I4P Section INDUSTRIAL ISOLATED SIGNAL CONVERTERS www fema es 27 Notes...