R O T A R Y
PAGE 42
S E R V I C E
Sensor Installation - Friction Machine ........................Fig 12.11
Section 12
SENSOR
12.1..... Sensor - All Machines
Sensor maintenance is dealt with in the operators manual and only
involves careful cleaning of both units and their lenses.
The sensors are mounted so that they are exactly aligned without
any adjustment so no provision is made to adjust them.
Sensor alignment can only be measured using an oscilloscope, but
if you suspect misalignment, first check that all fixing screws are
secure and that none of the relevant components are damaged.
When swinging the upper sensor assembly away from its mounting
take great care not to strain or trap it’s cable and if you are
clearing a paper jam avoid bending the input bed as this may result
in an excessive gap between upper and lower sensors.
Side Frame
(Clutch Side)
Upper Tie-Bar
Upper Sensor
Cable
Lower
Sensor Cable
Cable Ties
Lower
Tie Bar
Lower Sensor
Mounting
Upper Sensor
Mounting
Support Shaft
Input Bed
Print Position Shaft
Cable Passes
Over Print Position Shaft
Upper & Lower
Sensor Cables