13
Corner rounding machine
ERM 1050
4.6 Noise emission
The specified values are emission values and therefore
do not represent safe workplace values. Even though a
relationship exists between particle emission and noise
emission levels, an inference cannot be made about
whether additional safety measures need to be imple-
mented. Factors which can significantly affect the emis-
sion level that presently exists at the workplace include
duration of the effect, characteristics of the workspace,
and other ambient influences. The permissible workplace
values may also differ from country to country. Neverthe-
less, this information is provided to help the operator
better assess hazards and risks. Depending on the loca-
tion of the machine and other specific conditions, the
actual noise emission values may deviate significantly
from the specified values.
Note: To keep the noise emission as low as possible, always use sharpened tools and operate the
machine at the correct speed.
Ear protection must always be worn; however, such
protection cannot be considered a substitute for properly
sharpened tools or the correct speed.
As per ISO 3744/94 - ISO 7960/95 Annex norms:
Idle functioning without
dust extractor:
Medium level of
acoustic pressure
Level of acoustic pressure of
operator’s entrance place
Level of acoustic pressure of
operator’s exit place
Idle
72 Decibel (A)
71 Decibel (A)
70 Decibel (A)
When working with
dust extractor
Medium level of
acoustic pressure
Level of acoustic pressure of
operator’s entrance place
Level of acoustic pressure of
operator’s exit place
Operating mode
74 Decibel (A)
73 Decibel (A)
74 Decibel (A)
4.5 Particle emission
The machine was tested for particle emissions according
to DIN 33893. The Wood Authority ascertained,
according to the “Principles for Testing Particle Emis-
sions” (workplace-related particle concentrations) of
woodworking machines, that the particle emission values
for this machine are notably below the currently valid
atmospheric limit of 2.0 mg/m³. This is certified by the
blue label “BG Wood Particle Tested”.
Note:
Flush trimming is the only operation which produces dust emission. Connecting the machine to an efficient
dust extractor system, which guarantees a speed of at least 20m/min. to the suction outlet, results in dust
emission values below the limit of 2mg/m³ as prescribed by current legislation.
Technical data