![Fein RSG Ex18a Original Instructions Manual Download Page 25](http://html1.mh-extra.com/html/fein/rsg-ex18a/rsg-ex18a_original-instructions-manual_3919598025.webp)
25
en
Line oilers
Compressed-air line oilers conduct a thinly oiled mist to the com-
pressed air and thereby create a constant, reliable lubrication for
pneumatically powered compressed-air tools.
The built-in air diaphragm adjusts automatically to the air passage.
The minimum pressure is 0.5 bar.
Setting
The oil quantity, measured in drops per minute, can be regulated
using the metering screw. To do this, turn the screw in the oiler
attachment anti-clockwise, approx. 1 revolution. The drops can be
seen in the inspection glass.
Operation
The filling level can be seen on the container. Due to the built-in,
pressure-regulating valve, topping up is possible during operation
without turning off the compressed air.
- Unscrew the filler plug.
- Fill the container with oil; do not use a funnel.
- Alternatively, dismount the container at the bayonet lock and
directly fill in oil. Mount container on again.
- Close the opening again with the filler plug.
The oiler is ready for operation.
Max. operating pressure and temperature
For filters and oil-mist lubricators with polycarbonate container, the
max. operating pressure is 16 bar to +30 °C max., and 10 bar to
+50 °C max.
The following oil types are to be used for the maintenance unit:
■
For light to normal loads, use HLP/ISO-VG22 hydraulic oil with
corrosion-protection properties (Order No. 3 21 32 017 05 0 -
0.25 l) or
■
For high loads, use HLP/ISO-VG46 hydraulic oil with corrosion-
protection properties (Order No. 3 21 32 006 01 7 - 0.5 l).
■
When not using for longer periods (several months), we recom-
mend using corrosion-protection oils with HD properties (load-
carrying capacity level: min. 8) before putting out of operation;
e. g. engine-preservation oils „Mobilarma 524“ (Mobil) or „Ensis
10W“ (Shell).
Under unfavourable operating conditions, cold temperatures
(below +3 °C) and/or high water content of the compressed air, the
motor can ice up. This can be avoided by using a commercially avai-
lable synthetic de-icing and lubrication agent, e.g. „Kilfrost“, or by
using „Renolin SDL 1808“ in conjunction with the metal container
of the maintenance unit! Drain the lines and oiler first. Avoid any
mixing, as this would reduce or nullify the de-icing effect. The
remaining lubrication film does not have to be removed.
■
Kilfrost Anti-icing agent (DEPRAG - Order No. 807287)
■
Kilfrost 400 (Weyer Indutec)
■
Renolin SDL 1808 (Fuchs) is a biologically degradable com-
pressed-air lubricant for restricted use when laying pipes for
drinking water! Please generally observe the relevant regulations,
legal provisions and the lubricant agent manufacturer's notes.
Flow pressure:
A flow pressure in excess of 6 bar leads to wear. A too low flow
pressure leads to performance reductions.
Concerning the compressed-air quality according to ISO 8573-1,
we recommend:
Guarantee.
The guarantee on the product is valid according to the legal regula-
tions in the country where it is marketed.
Milling tools and accessories.
Circular saw blades
Form 1, HSS, for gear type:
a, b - for machining steel pipes
Form 2, HSS, for gear type:
b - for machining cast iron pipes
I
J
Class
Resi-
dual
Oil
Residual Dust
Residual Water
[mg/m
3
] Particle
size
[μm]
Concen-
tration
(max.)
[mg/m
3
]
Pres-
sure
dew
point
[°C]
Concen-
tration
(max.)
[g/m
3
]
For
oiled air
4
5
15
8
+3
6
For
unoiled
air
3
1
5
5
-20
0,88
Ø
Width Weight Number
of teeth
Max. cutting
depth
Reference num-
ber
[mm] [mm]
[kg]
[mm]
160
4
0,5
50
25
6 35 02 022 00 6
180
4
0,7
60
35
6 35 02 037 00 8
200
4
0,9
64
45
6 35 02 053 00 7
220
5
1,3
70
68
6 35 02 041 00 1
Ø
Width Weight Number
of teeth
Max. cutting
depth
Reference num-
ber
[mm] [mm]
[kg]
[mm]
160
4
0,5
40
25
6 35 02 050 00 1
180
4
0,7
46
35
6 35 02 098 00 0
200
4
0,9
50
45
6 35 02 099 00 4