10
en
Emission values for sound and vibration
(Two-figure – specifications as per ISO 4871)
Sound emission
AGSZ18-280 BL
(**)
AGSZ18-280 LBL
(**)
AGSZ18-90 LBL
(**)
A-weighted emission pressure power
level measured at the workplace
L
pA
(re
20 μPa), in decibels
84
85
85
Measuring uncertainty
K
pA
, in decibels
3
3
3
Measured A-weighted sound power level
L
wA
(re 1 pW), in decibels
95
96
96
Measuring uncertainty
K
wA
, in decibels
3
3
3
C-weighted peak sound pressure level
measured at the workplace
L
pCpeak
, in
decibels
98
98
98
Measuring uncertainty
K
pCpeak
, in decibels
3
3
3
Vibrations
(Ø 25 mm)
Mean vibrational value for surface grinding
with straight grinder
h,SG
, in
–
m/s
2
–
ft/s
2
5.0
16.4
5.0
16.4
1.0
3.3
(Ø 50 mm)
Mean vibrational value for surface grinding
with straight grinder
h,SG
, in
–
m/s
2
–
ft/s
2
12.0
39.4
12.0
39.4
2.0
6.6
Mean vibrational value for polishing with
straight grinder
h,P
, in
–
m/s
2
–
ft/s
2
–
–
–
–
3.0
9.8
Measuring uncertainty
K
, in
–
m/s
2
–
ft/s
2
1.5
4.9
1.5
4.9
1.5
4.9
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
OBJ_BUCH-0000000289-001.book Page 10 Wednesday, November 22, 2017 8:24 AM