5.5.1 Reader Setting for Indicator
The ISOStart software can be used to set the Reader configuration so that the output 2 or the
relays 1 to 3 opens or closes when a Transponder is read.
Step
Action
Note
1
Start ISO Start Software
2
Select “Configuration” and
click on “Read” to read the
complete configuration.
3
Operating Mode
Select Buffered Read Mode.
4
Set by clicking on „Apply“.
5
Digital IO:
Output2 / Sounder
Output Idle Mode: OFF
Idle Flash Mode: 1Hz
Setting Time: 10
„Setting Time“ set the dura-
tion time of output 2 for the
alarm.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign Output 2 to antenna
to all antennas of the set up
„True“ means: Output 2 will
be active if the reader read a
valid transponder at the cor-
responding antenna.
5
Set by clicking on „Apply“.