5.4.3 Testing the performance
For testing the performance you have to switch the reader to one of the Automatic Modes.
See 5.6Activating the Automatic Mode.
A read transponder will be displayed by a blue LED on the reader or by the LED light of the
antenna. See also
5.5.1Reader Setting for Indicator
In this test the capture area of the gate antenna described in
is checked. For
other tags or other configurations the indicated ranges and read areas may differ accordingly.
Fig. 22: Performance Test of the gate antenna
The test begins by checking the read range outside the gate (see Fig. points
and
), assuming
the configuration and locality permit it. If the tag is oriented parallel to the antenna towards the
outside, a read range of 65 to 75 cm should be achieved.
The three tag orientations are checked inside the gate. This corresponds to the lines and
orientations
.
Now slowly move the tag in the vertical and parallel direction with respect to
the antenna along the line
from one side to the other. The tag should always be read.
Then repeat this along the line
in the vertical tag direction transverse to the antenna and on the
line
in the horizontal tag orientation. Here again the tag should always be read.
The tag should be read within the gate when moving horizontally through the gate in all
three read orientations.
If one or more „holes“ are detected, check the noise values on the Reader (see