OBID i-
scan
®
Installation
ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH
Page 24 of 74
M91201-5e-ID-B.doc
5.3 Gate Configuration and Setup using Antennas Type -A and -B
5.3.1 Required Components
To construct the gate you need the following components:
-
Qty. 1 ID ISC.ANT1700/740-A Clear
(incl. Qty. 1 ID ISC.NET24V-B Power Supply Unit)
-
Qty. 1 ID ISC. ANT1700/740-B Clear
-
Qty. 1 ID ISC.NET24V-B Power Supply Unit
-
Power cable, interface cable and connection cable for the DC power supplies (2-wire,
twisted)
-
Mounting materials (screws, anchors)
Optional:
-
Qty. 2 ID ISC.ANT1700/740-AGP Acrylic glass plate windows for Clear antenna.
To calibrate the Reader you will need the software
-
ISOStart Version 2011 Version 8.03 or higher
and for tuning the antennas the service software
-
DATuningTool Version 1.10 or higher
on a personal computer running under Microsoft
®
Windows
®
. The Service Software can be