TIMEOUT (FWI):
With this parameter the Frame waiting time (FWT) according ISO14443-4 could be select
by the user
TIMEOUT
(FWI)
approx. Frame waiting time
(FWT)
0
1 ms
1
1 ms
2
2 ms
3
3 ms
4
5 ms
5
10 ms
6
20 ms
7
39 ms
8
78 ms
9
155 ms
10
310 ms
11
619 ms
12
1237 ms
13
2474 ms
14
4948 ms
15..254
- not allowed -
255
automatically
NOTICE:
If TIMEOUT = 255 is chosen the Reader used the FWI as transmitted from the
Transponder.
The value of TIMEOUT must be considered for calculating the TR-RESPONSE-
TIME (see CFG1)
REQUEST-BLOCK:
This Parameter with variable length is provided for the transparent data transfer to the
Transponder. Refer to ISO 14443-4, chapter "Block Format"
Prologue filed
Information
field
Epilogue field
PCB
[CID]
[NAD]
[INF]
EDC
1 Byte
1 Byte
1 Byte
x Byte
2 Byte
NOTICE:
PCB is mandatory for each command whereas the parameters in [ ] brackets are op-
tional. For further Information please see ISO/IEC ISO14443-4