6.1.1. [0x01] Inventory
This command reads the UID of all Transponders inside the detection range. The reply behavior of
this command can be configured by the Anticollision parameter of configuration block 3.6. CFG5:
Anticollision.
REQUEST-DATA
6
7
8
[0x01]
MODE
[0x00]
RESPONSE-DATA see:
6.1.1.1. Response-Data - ISO 14443A (TR-TYPE = 0x04)
6.1.1.2. Response-Data - ISO 14443B (TR-TYPE = 0x05)
6.1.1.3. Response-Data – ISO15693 (TR-TYPE = 0x03)
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
MORE
-
-
-
-
-
-
-
MORE:
this bit can be used, to read out the whole UIDs, after the Reader had signalized
more data sets with status 0x94 (see:
ANNEX C: Index of Status Bytes
.
b0:
new Inventory requested
The reader carries out a new inquiry, which Transponder are in his detec-
tion range.
b1:
more data requested
The reader response contain the UIDs which are not transferred with the
last response because of the status 0x94.
DATA-SETS:
Number of Transponder data sets to be transferred in this reader response.
TR-TYPE:
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
TYPE_NO
TYPE_NO:
Displays
the Transponder type of the present Transponder