OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 62 of 126
H01114-0e-ID-B.docx
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
BANK_NR
BANK_NR:
Defines the memory area on the transponder.
b00
reserved
b01
reserved
b10
reserved
b11
User memory bank
DB-ADR:
First block number to be locked. Depending on EXT_ADR. First block can be any value be-
tween 0 and 255 or 0 and 65535.
DB-N:
Number of data blocks to be locked from the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on the interface transmit buffer size TX-BUF. The
maximum number of DB-N is:
(TX-BUF - 10 )/(DB-Size+1) Standard Protocol
(TX-BUF - 12 )/(DB-Size+1) Advanced Protocol
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
DB-ADR-E:
Block number where the error occurred.