MWD BPC-H / MWD BPC-HU
Comissioning
EN
FEIG ELECTRONIC GmbH
37/74
MWD_BPC-H-HU_ver4_Manual_rev0_mul
5.2.2 Connect motion detector to door controller with the control unit TST UTH
If the TST UTH control unit is also connected to the door controller, the yellow switch on the door
controller board must be changed. The terminating resistor in the TST UTH control unit is permanently
installed.
1. Pull down the yellow switch (Figure 5).
In position ON no TST UTH is used (factory
setting).
Figure 5: Switch to control unit TST UTH
2. Connect the first motion detector and the
TST UTH to the door controller (Figure 6).
3. Test the operational readiness of the motion
detector and the control unit TST UTH.
Figure 6: Connecting to the door controller with
control unit TST UTH
5.3 Display during operation
The motion detector has two LEDs that indicate the current status of the motion detector. The following LED
signals are possible:
Table 2: LED display during operation
State of LED
Description
yellow
red
OFF
No power supply
Flashes 1x/sec.
OFF
Ready / no object detected
ON
ON
Channel 1 and 2: object detected
ON
X
Channel 1: object detected
X
ON
Channel 2: object detected
OFF
flashes 4 x/sec.
Bus connection is incorrect or no communication to the door
controller
Flashes 2x/second synchronously
Motion detector aktivated for configuration