5. Innitial operation
In addition to the configuration parameters described in this installation instructions the reader
have a great number of configuration parameters which are to be set with software commands
(watch: "System-manual standard reader of the ID RW-family").
Note:
After switch-on the reader or after a reset, the reader runs through an initialised mode for
about 10 seconds (the RUN-LED V201 flashes fast). The reader can not communicate with
Transponder at this time.
5.1 Interface configuration with jumper
With the jumpers J1 - J8 the asynchronous interface can be configured as RS232 (V24 turn-off
level), RS485 or RS232-TTL.
Jumper
Position: 1 - 2
Position: 2 - 3
1
RS485
RS232
2
RS485
RS232
3
RS232
RS232 - TTL
4
RS232
RS232 - TTL
5
Pull-Up to RS485 - B
without Pull-Up to RS485 - B
6
Pull down to RS485 - A
without pull down to RS485 - A
7
Terminating resistor
RS485 - AMP
⇔
RS485 - B
without terminating resistor
RS485 - AMP
⇔
RS485 - B
To selecting the interface type the jumpers J1 to J4 must be inserted in accordance with the table
standing below.
Interface
J1 and J2
J3 and J4
RS485
1-2
any
RS232 - V24
2-3
1-2
RS232 - TTL
2-3
2-3