4.2.2 Configuration
of a Gate Antenna
The connection of the components is shown in Fig. 18. We recommend supplying the Reader and
Power Splitter using two separate power supplies.
Fig. 18: Component connection for a standard Gate Type A + B
The coax cables have fixed lengths and may not be shortened and therefore need to be tied into
small loops (see Fig. 19). Tie all cables as far away from the antenna conductor as possible. The
cables must never be allowed to contact the copper tube.
Fig. 19: Tying the cables
X2
X3
X1
3,60m
2 Tuning-Boards of
Antenna ID ISC.ANT1400/760
Power Splitter
ID ISC.ANT.PS-B
X1
1,35m
X4
Toriod core
Long Range Reader
ID ISC.LR2000
IN1
X9, Pin1+3
DC Power supply
24V