5.3.2 Testing the performance
An alarm will be notified by the Alarm LED light of the antenna and the Alarm buzzer. See also
5.4.1 Reader Setting for Alarm Indicators
In this test the capture area of the gate antenna is checked. For different tags or other
configurations the ranges and read areas may differ.
Regarding used tags please refer
Fig. 11: Performance Test of the gate antenna
There is a big difference between an RF gate an the UHF gate. For UHF it is not sufficient that a
tag is detected. The UHF gate has to detect the moving through the gate. So the test should start
at least 1,75m upfront the gate and the tag has to be moved up to at least 1.75m behind the gate.
The possible 3 tag orientations can be tested - horizontal in walk direction, horizontal 90° to walk
direction and vertical.