![Feig Electronic ID ISC.ANT.U500/270 Installation Manual Download Page 25](http://html1.mh-extra.com/html/feig-electronic/id-isc-ant-u500-270/id-isc-ant-u500-270_installation-manual_3906863025.webp)
Identification
Installation
ID ISC.ANT.U500/270
–GA/-GB UHF-Gate
FEIG ELECTRONIC GmbH
Page 25 of 54
M71060-1e-ID-B
5.2.2 Configuration of the Gate Antennas
Almost, all cable should be mounted already. Normally, the antenna cable 1+2 from antenna Type
GB has to be connected antenna cable 1+2 at the type GA antenna 1:1
Fig. 8: Connecting the components for a gate consisting of two antennas
If the antenna cables from antenna type A to antenna type B have not been connected in the
right way or there is an error, the Alarm LED of antenna type A will flash after start up. If
cables are connected right , the alarm LED of both sides will be switched on shortly.
The cable from antenna type GB to the antenna type GA should preferably be connected shortly.
Unused cable lengths are possible and should be tied in antenna B type..
Fig. 9: Unused coaxial cables are tied in antenna Type B
1
2