5.4 Setting the Alarm Indicators (Alarm buzzer and Alarm LED lights)
5.4.1 Reader Setting for Alarm Indicators
The Alarm buzzer and the Alarm LED of antenna type GA and GB is constructed by the UPC.
Via ISOStart software can be set different parameters for Alarm LED and/or Alarm Buzzer.
Step
Action
Note
1
Start ISOStart Software
2
Select “Configuration” and
click on “Read” to read the
complete configuration.
3
Operating Mode
Setting Time:
with
„Setting Time“
set
time of LED and Buzzer
for alarm duration.
(20 means 2 seconds)
(e.g. 20 x 100ms)