Feellife Air Smart T1 User Manual Download Page 34

 

 

FCC Warning  

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.  
 
Any Changes or modifications not expressly approved by the party responsible for compliance could 
void the user's authority to operate the equipment.  
 

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures:  

 

-Reorient or relocate the receiving antenna.  

 

-Increase the separation between the equipment and receiver.  

 

-Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.  

 

-Consult the dealer or an experienced radio/TV technician for help.  

 

 

The device has been evaluated to meet general RF exposure requirement. The device can be used in 
portable exposure condition without restriction.

 

 

 

Summary of Contents for Air Smart T1

Page 1: ...1 User Manual for SPIROMETER Model Air Smart T1 Doc LFS EN UM 24D Issue date Apr 2 2021 Rev V1 0...

Page 2: ...tions 8 7 Cleaning and Disinfection 18 8 Storage and Maintenance 19 9 Contraindications Precautions and suggestive contents 19 10 Trouble Shooting 21 11 Note Warning 22 12 After sales Service 23 13 Sy...

Page 3: ...ct use of this product please read this instruction for use carefully before using Please keep this instruction for use in a place where convenient for reading at any time The illustrations in this in...

Page 4: ...C FEV1 FEV1 FVC PEF etc The spirometer is intended to be used by a physician or by a patient under the instruction of a physician or paramedic 2 Working Principle Inhale deeply seal your lips around y...

Page 5: ...r Model Air Smart T1 Internal power supply DC 3 7 V 2000mAh rechargeable lithium battery External power supply With DC 5 V 1 A adapter Display mode LCD display Flow range 16 l s deviation 10 or 0 3 l...

Page 6: ...smission has communication protocol requirements 4 0 4 Service life The main unit 5 years Turbine 1 year 5 Shelf life Disposable mouthpiece 3years Turbine 3years 5 Installation Guideline 5 1 Turbine a...

Page 7: ...7 Caution 1 The disposable mouthpiece is a paper material it is designed for single user and single use It is not allowed for multi users...

Page 8: ...of 30 mm is of common use and in general easily procured 5 4 Power supply preparation 1 This device uses 3 7 V rechargeable lithium battery It is not equipped with a power adapter Please use an adapte...

Page 9: ...on If you need to replace the battery please consult the manufacturer 6 Operating Instructions 6 1 ON OFF key After assembly long press about 3 seconds the ON OFF key to turn on off the device 6 2 Mea...

Page 10: ...full chest and abdominal expansion to avoidexternal restrictions on lung function 1 After turning on the device it will locate in selective interface shown as Figure 1 press UP or DOWN key to select Y...

Page 11: ...to the predicted value vividly The comparison of measured value with the reference value in same situation It is red when the value is lower than 50 which means that the user should pay attention to...

Page 12: ...ey to select corresponding item then press CONFIRM key to enter its sub menu methods are as followings Figure 5 Menu interface Personal information Under Menu interface select Personal information to...

Page 13: ...is 6 101 Adjustable range of Height is 80 241 cm Adjustable range of Weight is 15 250 Kg The equation of predicted value can be set in Equation item including ECSC KNUDSON and USA 3 Exit In Personal...

Page 14: ...d change vividly which is convenient for user to compare If there are too much data press UP or DOWN key in the curve to browse all data trend in turn Press CONFIRM key to return to Data Management in...

Page 15: ...t interface The Health status indicator will show in accordance with the parameter you set as shown to Figure 3 Figure 12 Denote value setting interface 5 Exit In Data Management interface select Exit...

Page 16: ...elect ON OFF Collect your phone and this device via Bluetooth You can review the data by this way How to use the Bluetooth Step 1 Install the APP according to scan the QR code Step 2 Open the Bluetoot...

Page 17: ...r Figure 14 Time setting interface 4 About You can select About in Settings interface to enter its sub menu and check the device name and software version then press CONFIRM or RETURN key you can retu...

Page 18: ...be searched and connected with other devices When the connection is built successfully the device displays data transmission icon Caution 1 This device will automatic power off when there is no operat...

Page 19: ...18 FEF75 Forced expired flow at 75 of FVC l s FEF2575 Forced expiratory flow between 25 and 75 of l s...

Page 20: ...f the main unit After cleaning let it air dry Do not put the device into water or other fluids Caution 1 The main unit cannot be cleaned or soaked in clean water so as to prevent water from entering i...

Page 21: ...ot twist the USB cable 5 If you have any trouble during using process please seek solutions according to Trouble Shooting section If this device still cannot work normally please contact the manufactu...

Page 22: ...Note Spirometry should be discontinued if the patient experiences pain during the maneuver Patients with potential contraindications that would prevent testing in the primary care setting may be test...

Page 23: ...g time and the data can t be displayed The start speed is too low the device does not measure Remeasure according to the Operational Guideline section Device malfunction Please contact the manufacture...

Page 24: ...er to Cleaning and Disinfection section Please keep the accessories dry when store them Please assure all the accessories assembled rightly before using Don t use this device under inflammable gas env...

Page 25: ...ctrical or electromagnetic fields near the medical device Waste disposal discard the main engine and accessories according to local laws and regulations The USB cable should be kept away from children...

Page 26: ...ildren or pets to prevent animal hair or dirt entering the turbine to affect its use 12 After sales Service 1 After this device is packed under the condition of following the storage and use regulatio...

Page 27: ...gulations Electromagnetic compatibility 13 1 Symbol description General symbol Description title General symbol Description title Date of manufacture General warning sign Manufacturer information Refe...

Page 28: ...application part for protection of defibrillation discharge effect no application part for defibrillation prevention 8 Whether there is signal output or signal input part there is signal input or sign...

Page 29: ...ice should assure that they are used in such an environment Immunity test IEC 60601 test level Compliance Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8kV contact 2kV...

Page 30: ...st IEC 60601 test level Compliance level Electromagnetic environment guidance 6Vrms in ISM and amateur radio bands 6Vrms in ISM and amateur radio bands Portable and mobile RF communicationsequipment s...

Page 31: ...red field strength in the location in which the device is used exceeds the applicable RF compliance level above the device should be observed to verify normal operation If abnormal performance is obse...

Page 32: ...E 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 14 Configuration List Item Quantity If Incl...

Page 33: ...Any repair service out of the scope of warranty will be charged accordingly 16 Manufacturer and Rep information FEELLIFE HEALTH INC Room 1903 Building A No 9 Furong Road Tantou Community Songgang Subd...

Page 34: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...