![Feel Good mr. steam AirButler Installation, Operation & Maintenance Manual Download Page 7](http://html1.mh-extra.com/html/feel-good/mr-steam-airbutler/mr-steam-airbutler_installation-operation-and-maintenance-manual_3822665007.webp)
6
®
Installation Instruction
Installation Instruction
Silicone Sealant
Cable
Wall
1⁄4" minimum
1⁄2" maximum
Sectional View
STEAM
ROOM
INTERIOR
Diagram 2
Installed Remote Temperature Probe
showing a minimum of 1/4” of the probe
exposed to steam room air
Diagram
5. Route the end of the probe cable with the temperature probe
through the wall into the steam room as shown in Diagram 2.
IMPORTAN
DO NOT
strain, staple, pinch or otherwise damage
the probe cable.
6. With a minimal length of the cable exposed apply silicone
(provided) to the hole in the wall as required to create a mois-
ture seal as shown in Diagram 2.
7. Push the temperature cable and probe into hole as required to
leave minimum 1/4”, maximum 1/2” of the bulb exposed as
shown in Diagram 3.
W ARNING Insure a minimum of 1/4” of the temperature
probe is exposed to the air. Failure to do so may interfere with
the ability to sense tempera-ture and may result in excessive
steam room temperatures.
The exposed area of the temperature probe must
be free of silicone or any materials or obstructions that pre-
vent direct exposure to the steam room air. Failure to do so
may interfere with the ability to sense tem-perature and may
result in excessive steam room temperatures.
NOTE:
For Illustrative Purposes Only. Drawings Not to Scale
1
AirTempo
Operating Instructions
The AirTempo features programmable temperature
control, programmable time duration, AromaSteam
ON/OFF, ChromaSteam
®
control and two personal
settings.
The LCD will be OFF until a button is pressed. The
LCD remains lit for 10 seconds after the last button
is pressed. When the steam generator turns OFF
the display will turn on and read OFF. While the
generator is steaming the LED above AROMA and
,"ÊÜÊ>ÌiÀ>ÌiÞÊv>à ÊiÛiÀÞÊÓÊÃiV`ð
Diagram 1
Diagram 2
ON/OFF
Time
ON/OFF
Diagram 1
Press the ON/OFF key for 1 second to start the
vÜÊvÊÃÌi>°Ê/ iÊ/i«iÀ>ÌÕÀiÊ-iÌÊ*ÌÊÃÊ
`ë>Þi`°Ê-Ìi>ÊÜÊLi}ÊÌÊvÜÊ>ÊviÜÊÕÌiÃÊ
after the control is turned ON. The duration re-
quired for the steam room to reach steam bathing
temperatures depends on the steam room
construction and steam generator specifications.
/Ê
ÃÌ«ÊÌ
iÊvÜÊvÊÃÌi>ÊLivÀiÊÌiÊiÝ«ÀiÃÊ«ÀiÃÃÊ
Ì
iÊ" É"ÊiÞ°ÊÊ-Ìi>Ê>ÞÊVÌÕiÊÌÊvÜÊ
for a short time after the control is turned OFF
SETTING THE STEAMBATH DURATION
Diagram 2
Press TIME key to set or display the steambath
duration time. The control is pre-set and will display
a TIME setting of 20 minutes (default setting). With
the TIME displayed, press the LEFT or RIGHT
arrows to set the desired duration time (2-60
minutes) in two minute increments.
Set the steam bathing temperature
according to personal preference, however it is
highly recommended to begin steam bathing at a
low temperature setting for a very short duration to
gauge comfort and safety levels.
!
WARNING
2