Feel Good mr. steam AirButler Installation, Operation & Maintenance Manual Download Page 17

16

Linear Steam Head

®

®

Installer Section 

Model 104480

 

  Steambath controls feature an integral or 

remote temperature sensor that senses room temperature. 
Install the linear steam head in a location where steam 
emission will not come in direct contact with the control or 
rem ote temperature sensor. Failure to follow these 
   instructions may result in poor temperature control, a 
hazardous condition, scalding or personal injury. 
 

  Only use the supplied high temperature 

silicone sealant as required to create a permanent moisture 
seal. Do not seal the steam head with grout or any other 
material. Failure to follow these instructions may result in 
leaks, and cause problems associated with leaks, moisture 
and property damage from leaks. 
 

  The linear steam head must be installed by a 

qualified and licensed plumber. Failure to use a qualified 
and licensed plumber may result in a leak within the wall 
cavity and cause problems associated with leaks, moisture 
and property damage from leaks. Failure to follow these 
instructions may result in elevated temperatures, a 
hazardous condition, scalding or personal injury. 
 

  Do not use black iron, galvanized, or plastic 

pipe for the steam line. Use only properly rated brass pipe 
or copper tubing in accordance with national and local 
plumbing codes. Using any piping material other than 
properly rated brass or copper piping may cause linear 
steam head damage and problems associated with leaks, 
moisture and property damage from leaks or steam. 
 

  Plumb rigid copper tubing or brass pipe from 

the steam generator to the linear steam head. Plumbing 
must not form traps or valleys. Failure to follow these 
instructions may result in leaks, and cause problems 
associated with leaks, moisture and property damage from 
leaks. Failure to follow these instructions may result in a 
hazardous condition, scalding or personal injury. 
 

  Do not modify or alter the linear steam head. 

Do not cover, block or insert any product that is not a 
MrSteam supplied linear steam head accessory with the 
linear steam head. Failure to follow these instructions may 
result in a leak within the wall cavity and cause problems 
associated with leaks, moisture and property damage from 
leaks. Failure to follow these instructions may result in a 
hazardous condition, scalding or personal injury. 
 

  Do not disassemble the steam head. The steam 

head is shipped fully assembled and requires no additional 
assembly. Failure to follow these instructions may result in a 
leak within the wall cavity and cause problems associated with 
leaks, moisture and property damage from leaks.  
 

  Before installing the linear steam head, read 

and follow the Installation and Operation Manual(s) provided 
with all system components ( generator, controls, 

accessories...etc.). If the installation and operation manuals are 
not available go to www.mrsteam.com for an online copy, or 
contact MrSteam Customer or Technical Services at 800-767-
8326 or 800-727-8326 for free copies. Failure to read and 
follow all the Installation and Operation Manuals may result in a 
leak within the wall cavity and cause problems associated with 
leaks, moisture and property damage from leaks. Failure to 
follow these instructions may result in inoperable system 
components, a hazardous condition, scalding or personal injury. 
 

  Consult with the manufacturer of any non-

heat resistant enclosures for elevated temperatures, steam,  
moisture compatibility or for suitability for use with steam. 
Failure to follow these instructions may result in the damage 
or failure of materials or products. Failure to follow these 
instructions may result in leaks, and cause problems 
associated with leaks, moisture and property damage from 
leaks. Failure to follow these instructions may result in a 
hazardous condition, scalding or personal injury. 
 

  Do not install a Linear Steam Head in an 

acrylic/fiberglass tub or shower enclosure. Failure to follow 
these directions may cause problems associated with leaks, 
moisture and property damage from leaks. Failure to follow 
these instructions may result in elevated temperatures, a 
hazardous condition, scalding or personal injury. 
 

  Do not locate the steam head where steam, 

elevated temperatures, moisture or water can contact any 
products, wall surfaces, materials, door seals, devices, 
electronics that are not designed for use with steam, 
elevated temperatures, moisture or water. Failure to follow 
these instructions may result in damage or improper 
operation of the products, wall surfaces, materials, door 
seals, devices or electronics. 
 

  The optional diverter reduces the steam 

emission zone by redirecting steam up the wall above the 
steam head (see page 6).  Installation of the diverter may 
result in the following: 

• Changes to the steam distribution in the room   
• Increase of the temperature of the wall and devices above 

the steam head 

• Surface condensation patterns on the walls and ceiling 

Always test the diverter to insure proper safety, installation 
and comfort. 
 

  Carefully inspect the Linear Steamhead and 

packaging for shipping damage. In the event of shipping 
damage, please contact the carrier for claim information. 
Our customer service department can assist you with 
product replacement.  
 

  Do not use abrasive cleansers or chemicals to 

clean the linear steam head. Use only water with mild soap 
and a non-abrasive sponge. The use of abrasive cleansers or 
chemicals will damage the finish on the linear steam head.

Summary of Contents for mr. steam AirButler

Page 1: ...Good Inc Rev 5 2022 Table of Contents AirTempo Wireless Control AromaSteam SteamHead Linear Steamhead SteamLinx Mobile App MS Super AutoFlush MX Autoflush Condensation Pan PUR100474 PUR100421 PUR10393...

Page 2: ...Installation Operation Maintenance Manual AirTempo Wireless Touch Control with Steamhead mr steam Feel Good Inc PUR100474 Rev 5 22...

Page 3: ...A occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperat...

Page 4: ...stalled inside or outside the steam room as a matter of personal preference If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the...

Page 5: ...on glass a peel and stick film is provided on pages 20 21 and may be used as a mask for a clean look from behind the glass Steam Generator 3 ft Cable Standard optional 30 or 60 cable available Wirele...

Page 6: ...i i i iV i i i i i i i V d The probe has an integral 30 cable Insure that the probe and or steam generator are located accordingly i v V L i L i 2 Drill a 5 16 inch diameter hole in the wall Do not o...

Page 7: ...E For Illustrative Purposes Only Drawings Not to Scale 1 AirTempo Operating Instructions The AirTempo features programmable temperature control programmable time duration AromaSteam ON OFF ChromaSteam...

Page 8: ...the TEMP key for 10 seconds The temperature units will toggle to Fahrenheit F or Celsius C USING AIRTEMPO AS A REMOTE TheAirTempocanberemovedfromits holder andusedas aremote control towarmupthesteamsh...

Page 9: ...ed by a number This is the software revision CO indicates the AirTempo control has lost communication with the steam generator Ensure all connections are secure between the steam generator and the tra...

Page 10: ...unications However there is no guarantee that interference will not occur in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be...

Page 11: ...l Flush Mount specify finish 104215XX Surface Bezel Surface Mount AirTempo Surface specify finish 104220 AirTempo Control Cable 3ft All 104117 30 30 ft Control Cable Optional 103990 60 60 ft Control C...

Page 12: ...in place Template For Flush Mount Kit Installation www mrsteam com Products information and specifications are subject to change without notice For more information call Sales Support at 1 800 76 STEA...

Page 13: ...Installation Operation Maintenance Manual AromaSteam SteamHead mr steam Feel Good Inc PUR100421 Rev 5 22...

Page 14: ...tant flooring install Acrylic Shield Part Number MS 103938 3 To prevent door seals from deteriorating do not locate the steam head where direct steam emission would contact door seals STEP 2 Install s...

Page 15: ...Installation Operation Maintenance Manual mr steam Feel Good Inc Linear Steam Head Residential Model 104480 IMPORTANT Leave this material with the homeowner PUR103936 Rev 5 22...

Page 16: ...esistant flooring install Acrylic Shield Part Number MS 103938 3 To prevent door seals from deteriorating do not locate the steam head where direct steam emission would contact door seals STEP 2 Insta...

Page 17: ...e linear steam head read and follow the Installation and Operation Manual s provided with all system components generator controls accessories etc If the installation and operation manuals are not ava...

Page 18: ...tlet Figure 2 3 4 NPT Steam Inlet 9 1 4 1 1 16 2 1 4 5 8 2 1 8 P104481 Linear Steam Head 104483 Faceplate 104484 Diverter 104482 AromaTray Bracket Adjustment Screws Adjustable Brackets Linear SteamHea...

Page 19: ...om construction Installer Section Model 104480 Figure 3 Figure 4 Steam Head Installation Stud Stud Steam Head Face Steam Outlet Level Copper Tubing or Brass Pipe Not Supplied 14 1 8 19 Linear SteamHea...

Page 20: ...led inside the steam room the control must be located 2 4 5 feet above the floor near the bather seating area 3 The control features an integral temperature sensor Locate the control in a location rep...

Page 21: ...tact with steam presentees a scalding hazard The steam head must be installed in a location to ensure that a steam bather will not be near the steam emission zone The diverter reduces the steam emisso...

Page 22: ...njury Because direct steam is very hot the diverter will be hot during the steam session and will remain hot for a period of time after steam session Never install remove or adjust a diverter when the...

Page 23: ...ing a steam bath session or for a period of time after the steam bath session may result in burns scalding or personal injury Failure to first read the instructions provided with the MrSteam Essential...

Page 24: ...Linear Steam Head using the video Use only these installation instructions for a safe and problem free installation Linear Steam Head NOTE Drawings are for illustrative purposes only Consult with qual...

Page 25: ...72 STEAM 2020 MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam...

Page 26: ...Installation Operation Maintenance Manual SteamLinx mr steam Feel Good Inc PUR100518 Rev 5 22...

Page 27: ...ZS Pg QOZZW U AbSO 1cab S AS dWQS Wb QO PS R e Z ORSR T abSO Q ZZ R OeW Ua T aQVS ObWQ c aSa Zg OQYOUS 1 bS ba AbSO W f eWbV 7 bSU OZ 1OPZS AbSO W f 0 O R 3bVS Sb 1OPZS eS Ac Zg O R 1OPZS 7 ab cQbW a...

Page 28: ...bVS W bS Sb BVS W RWQOb ZWUVb AbSO W f eWZZ b PS WZZc W ObSR 0ZcS C Wba O S Q SQbSR Q SQbZg C Wba O S cb T O US b OW SR Bc P SOYS TT 7 ac S AbSO W f Wa Q SQbSR b bVS abSO US S Ob CaS O O S QZW aW WZO...

Page 29: ...Installation Operation Maintenance Manual S Su er Auto lu mr steam Feel Good Inc PUR100200E Rev 5 22...

Page 30: ...llowing each use A time delay allows the water to cool down about two hours before it drains resulting in a safe and gentle operation BOX CONTENTS AutoFlush System Valve with Cord Installation Instruc...

Page 31: ...ded can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosure or an...

Page 32: ...Installation Operation Maintenance Manual X Auto lu mr steam Feel Good Inc PUR100532 Rev 5 22...

Page 33: ...ollowing each use A time delay allows the water to cool down about two hours before it drains resulting in a safe and gentle operation BOX CONTENTS AutoFlush System Valve with Cord Installation Instru...

Page 34: ...toFlush System valve will open and may discharge boiling water SWEAT FITTINGS When using sweat fittings use only tin base solder with a melting point below 600 degrees F Do not overheat Ends of water...

Page 35: ...Installation Operation Maintenance Manual Conden ation Pan mr steam Feel Good Inc TS0012 Rev 5 22...

Page 36: ...in accordance with applicable national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an int...

Page 37: ...1 Express Steam Feel GoodInc FromBathroomto Spa iButler iGenie iSizing iSteam MakingWellness a Way of Life Music Therapy Spa Package Steam on Demand Steam Home iTempo iTempo Plus SmartSizing SteamSta...

Reviews: