Feel Good mr. steam AirButler Installation, Operation & Maintenance Manual Download Page 20

Installer Section 

Linear Steam Head

®

®

NOTE:

 Drawings are for illustrative purposes only.

 

Consult with qualified designer, architect or contractor for steam room construction.

Model 104480

The steam head is supplied with an optional faceplate. It 
is not required for the functional operation of the steam 
head. The faceplate is a decorative accessory and is 
available in (8)  finishes.  

An optional Escutcheon (remodel plate) is available for 
purchase, it's larger than faceplate and is available in (8) 
finishes. 

In 

STEP 4

, instead of positioning the steam head face 

to be flush with the finished wall face, position the steam 
head so that the steam head face will be 1/8” recessed 
with the finished wall  (see Fig. 4). This will provide 
clearance for the faceplate.  

Apply silicone to the front of Linear Steam Head and 
firmly press the faceplate against the face of the steam 
head. Secure the faceplate as required until the silicone 
sets.  

Return to 

STEP 5

 on page 4 to complete the 

installation.

1. Determine the desired installation location of the control.

The iSteam®, iTempo™ and iTempo/Plus™ controls are
designed to be installed inside or out-side the steam room
as a matter of personal prefer-ence. If the control is installed
inside the steam room the control must be located:

2. 4-5 feet above the floor near the bather seating area

3. The control features an integral temperature sensor. Locate

the control in a location representative of the desired
steambathing temperatures.
Do not locate the control above or near the steam head or
direct steam emissions.

4. On a vertical wall

The control cable length is 30 feet. Insure that the control
and/or steam generator are located accordingly. An optional

60 foot cable is available, PN 103990-60 for iTempo and PN 
104117-60 for iSteam. Contact a MrSteam technical service 
representative if a 60 foot cable is required. 

IMPORTANT NOTE:

 If the control is installed outside the 

steamroom a Remote Temperature Probe Part Number MSTS 
must be installed inside the steam room, depending on the 
control. Insure MrSteam steam generator is iSteam or iTempo 
compatible and has a serial number 900000 or higher. If 
iSteam is used with a generator having serial number less than 
1174000, contact MrSteam technical support for an upgraded 
PC board. 

See instructions for the MSTS Temperature Probe (located in 
the Control Installation Manual related to your specific control 
package) before rough-in or installation of control. 

Figure 5

Optional Faceplate Installation 

Cement Board

Thin Set

Finished 

Wall Surface

Silicone

Faceplate

Silicone

Apply Silicone on surface

Faceplate

Figure 4

Vapor Barrier

19

Summary of Contents for mr. steam AirButler

Page 1: ...Good Inc Rev 5 2022 Table of Contents AirTempo Wireless Control AromaSteam SteamHead Linear Steamhead SteamLinx Mobile App MS Super AutoFlush MX Autoflush Condensation Pan PUR100474 PUR100421 PUR10393...

Page 2: ...Installation Operation Maintenance Manual AirTempo Wireless Touch Control with Steamhead mr steam Feel Good Inc PUR100474 Rev 5 22...

Page 3: ...A occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperat...

Page 4: ...stalled inside or outside the steam room as a matter of personal preference If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the...

Page 5: ...on glass a peel and stick film is provided on pages 20 21 and may be used as a mask for a clean look from behind the glass Steam Generator 3 ft Cable Standard optional 30 or 60 cable available Wirele...

Page 6: ...i i i iV i i i i i i i V d The probe has an integral 30 cable Insure that the probe and or steam generator are located accordingly i v V L i L i 2 Drill a 5 16 inch diameter hole in the wall Do not o...

Page 7: ...E For Illustrative Purposes Only Drawings Not to Scale 1 AirTempo Operating Instructions The AirTempo features programmable temperature control programmable time duration AromaSteam ON OFF ChromaSteam...

Page 8: ...the TEMP key for 10 seconds The temperature units will toggle to Fahrenheit F or Celsius C USING AIRTEMPO AS A REMOTE TheAirTempocanberemovedfromits holder andusedas aremote control towarmupthesteamsh...

Page 9: ...ed by a number This is the software revision CO indicates the AirTempo control has lost communication with the steam generator Ensure all connections are secure between the steam generator and the tra...

Page 10: ...unications However there is no guarantee that interference will not occur in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be...

Page 11: ...l Flush Mount specify finish 104215XX Surface Bezel Surface Mount AirTempo Surface specify finish 104220 AirTempo Control Cable 3ft All 104117 30 30 ft Control Cable Optional 103990 60 60 ft Control C...

Page 12: ...in place Template For Flush Mount Kit Installation www mrsteam com Products information and specifications are subject to change without notice For more information call Sales Support at 1 800 76 STEA...

Page 13: ...Installation Operation Maintenance Manual AromaSteam SteamHead mr steam Feel Good Inc PUR100421 Rev 5 22...

Page 14: ...tant flooring install Acrylic Shield Part Number MS 103938 3 To prevent door seals from deteriorating do not locate the steam head where direct steam emission would contact door seals STEP 2 Install s...

Page 15: ...Installation Operation Maintenance Manual mr steam Feel Good Inc Linear Steam Head Residential Model 104480 IMPORTANT Leave this material with the homeowner PUR103936 Rev 5 22...

Page 16: ...esistant flooring install Acrylic Shield Part Number MS 103938 3 To prevent door seals from deteriorating do not locate the steam head where direct steam emission would contact door seals STEP 2 Insta...

Page 17: ...e linear steam head read and follow the Installation and Operation Manual s provided with all system components generator controls accessories etc If the installation and operation manuals are not ava...

Page 18: ...tlet Figure 2 3 4 NPT Steam Inlet 9 1 4 1 1 16 2 1 4 5 8 2 1 8 P104481 Linear Steam Head 104483 Faceplate 104484 Diverter 104482 AromaTray Bracket Adjustment Screws Adjustable Brackets Linear SteamHea...

Page 19: ...om construction Installer Section Model 104480 Figure 3 Figure 4 Steam Head Installation Stud Stud Steam Head Face Steam Outlet Level Copper Tubing or Brass Pipe Not Supplied 14 1 8 19 Linear SteamHea...

Page 20: ...led inside the steam room the control must be located 2 4 5 feet above the floor near the bather seating area 3 The control features an integral temperature sensor Locate the control in a location rep...

Page 21: ...tact with steam presentees a scalding hazard The steam head must be installed in a location to ensure that a steam bather will not be near the steam emission zone The diverter reduces the steam emisso...

Page 22: ...njury Because direct steam is very hot the diverter will be hot during the steam session and will remain hot for a period of time after steam session Never install remove or adjust a diverter when the...

Page 23: ...ing a steam bath session or for a period of time after the steam bath session may result in burns scalding or personal injury Failure to first read the instructions provided with the MrSteam Essential...

Page 24: ...Linear Steam Head using the video Use only these installation instructions for a safe and problem free installation Linear Steam Head NOTE Drawings are for illustrative purposes only Consult with qual...

Page 25: ...72 STEAM 2020 MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam...

Page 26: ...Installation Operation Maintenance Manual SteamLinx mr steam Feel Good Inc PUR100518 Rev 5 22...

Page 27: ...ZS Pg QOZZW U AbSO 1cab S AS dWQS Wb QO PS R e Z ORSR T abSO Q ZZ R OeW Ua T aQVS ObWQ c aSa Zg OQYOUS 1 bS ba AbSO W f eWbV 7 bSU OZ 1OPZS AbSO W f 0 O R 3bVS Sb 1OPZS eS Ac Zg O R 1OPZS 7 ab cQbW a...

Page 28: ...bVS W bS Sb BVS W RWQOb ZWUVb AbSO W f eWZZ b PS WZZc W ObSR 0ZcS C Wba O S Q SQbSR Q SQbZg C Wba O S cb T O US b OW SR Bc P SOYS TT 7 ac S AbSO W f Wa Q SQbSR b bVS abSO US S Ob CaS O O S QZW aW WZO...

Page 29: ...Installation Operation Maintenance Manual S Su er Auto lu mr steam Feel Good Inc PUR100200E Rev 5 22...

Page 30: ...llowing each use A time delay allows the water to cool down about two hours before it drains resulting in a safe and gentle operation BOX CONTENTS AutoFlush System Valve with Cord Installation Instruc...

Page 31: ...ded can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosure or an...

Page 32: ...Installation Operation Maintenance Manual X Auto lu mr steam Feel Good Inc PUR100532 Rev 5 22...

Page 33: ...ollowing each use A time delay allows the water to cool down about two hours before it drains resulting in a safe and gentle operation BOX CONTENTS AutoFlush System Valve with Cord Installation Instru...

Page 34: ...toFlush System valve will open and may discharge boiling water SWEAT FITTINGS When using sweat fittings use only tin base solder with a melting point below 600 degrees F Do not overheat Ends of water...

Page 35: ...Installation Operation Maintenance Manual Conden ation Pan mr steam Feel Good Inc TS0012 Rev 5 22...

Page 36: ...in accordance with applicable national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an int...

Page 37: ...1 Express Steam Feel GoodInc FromBathroomto Spa iButler iGenie iSizing iSteam MakingWellness a Way of Life Music Therapy Spa Package Steam on Demand Steam Home iTempo iTempo Plus SmartSizing SteamSta...

Reviews: