- 26 -
Cabinet Grills &Air Duct (All refrigerated self-contained and remotes with condo pan)
IMPORTANT: Federal Industries reserves the right to deny warranty if the cabinet is not ducted to
allow proper condenser and condensate air intake and discharge, or if the cabinet louvers are not
installed properly, or if condenser air intake and discharge air is blocked or located near a source of
heat.
The condenser air intake and discharge must be separated and vented out of the cabinet compartment for
case to operate. The required louver grills and expandable ducts for both intake and discharge are provided
with case. On Remotes, the louvers are required to vent the moist condensate air.
Note: The louvered panels mounted to condenser compartment are located on the back of the compartment
and solid panels are mounted to front of the compartment when shipped from factory. This set up is for air
intake and discharge out of the back of the cabinet. The intake and discharge louvered panels can be moved
to front of compartment and the solid panels moved to the back of compartment if air intake and discharge
is required out of front of cabinet
The Outer Duct must be adjusted so that the gasket seals against the Cabinet Door. Remove the (4) screws
located inside of the Outer Duct. There are multiple holes in the Outer Duct. Move Outer Duct to desired
depth and reinstall (4) screws. Open & close door and be sure Gasket seals hits door
Center the supplied Grills on outside of Cabinet Doors and mark holes onto doors. Drill 1/8 holes into door
in marked positions. With Grill flanges against door screw Grill to cabinet door with (4) supplied #8 x1-1/4
screws.
Summary of Contents for ITR Series
Page 14: ...14 Counter ITR60 Self Contained Counter ITRSS60 Self Contained...
Page 15: ...15 Floor ITR ITRSS 36 Self Contained...
Page 16: ...16 Floor ITR ITRSS 48 Self Contained Floor ITR60 Self Contained...
Page 17: ...17 Floor ITRSS60 Self Contained Refrigerated Remote Models...
Page 18: ...18 All ITR Counter Remote All ITR Floor Remote All ITRSS Counter Remote...
Page 19: ...19 All ITRSS Floor Remote Floor ITD ITDSS NON Refrigerated...