- 6 -
GENERAL ELECTRICAL & GROUNDING
DANGER:
Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.
MODEL
PERMANENT CONNECTED AMPS
CORD CONNECT AMPS/NEMA PLUG
COMPRESSOR LRA
ITR3626 & ITR3634
MIN CIRCUIT AMPACITY 13.9/ MAX FUSE SIZE 20
TOTAL AMPS 8.7 / 5-15
TOTAL AMPS 8.7 / 5-15
ITR4826 & ITR4834
MIN CIRCUIT AMPACITY 16.9/ MAX FUSE SIZE 20
TOTAL AMPS 10.7 / 5-15
TOTAL AMPS 10.7 / 5-15
ITR6026 & ITR6034
MIN CIRCUIT AMPACITY 17.3/ MAX FUSE SIZE 20
TOTAL AMPS 11.0 / 5-15
TOTAL AMPS 11.0 / 5-15
ITRSS3626 & ITRSS3634
MIN CIRCUIT AMPACITY 17.11/ MAX FUSE SIZE 20
TOTAL AMPS 13.6 / 5-20
TOTAL AMPS 13.6 / 5-20
ITRSS4826 & ITRSS4834
MIN CIRCUIT AMPACITY 20/ MAX FUSE SIZE 25
TOTAL AMPS 13.8 / 5-20
TOTAL AMPS 13.8 / 5-20
ITRSS6026 & ITRSS6034
MIN CIRCUIT AMPACITY 13.65/ MAX FUSE SIZE 20
TOTAL AMPS 10.1 / 6-15
TOTAL AMPS 10.1 / 6-15
MODEL
VOLTAGE
PERMANENT CONNECTED AMPS
ITR3626 & ITR3634
ITRSS3626 & ITRSS3634 120V/60H/1PH
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
ITR4826 & ITR4834
ITRSS4826 & ITRSS4834
120V/60H/1PH
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
ITR6026 & ITR6034
ITRSS6026 & ITRSS6034
120V/60H/1PH
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
MODEL
PERMANENT CONNECTED AMPS
CORD CONNECT AMPS/NEMA PLUG
ITD3626 & ITD3634
ITDSS3626 &ITDSS3634
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
TOTAL AMPS 2.0 / 5-15
ITD4826 & ITD4834 ITDSS
4826 & ITDSS4834
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
TOTAL AMPS 2.0 / 5-15
ITD6026 & ITD6034
ITDSS6026 & ITDSS 6034
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
TOTAL AMPS 2.0 / 5-15
SELF CONTAINED
VOLTAGE
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
230/60H/1PH
DRY NON REFRIGERATED
VOLTAGE
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
REMOTE
(E3788 EXCEL)
Refrigerated Permanent Connected
-Only a licensed electrician must perform all case electrical connections.
-All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
electrical standards.
-A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
-The electrical service must be grounded upon installation.
-See the electrical data plate located at the rear of the case for proper circuit size and wire ampacity.
-The electrical connection box is accessible from the rear of the case with rear grill removed. See grill
removal section of this manual for grill removal procedure.
Summary of Contents for ITD Series
Page 14: ...14 Counter ITR60 Self Contained Counter ITRSS60 Self Contained...
Page 15: ...15 Floor ITR ITRSS 36 Self Contained...
Page 16: ...16 Floor ITR ITRSS 48 Self Contained Floor ITR60 Self Contained...
Page 17: ...17 Floor ITRSS60 Self Contained Refrigerated Remote Models...
Page 18: ...18 All ITR Counter Remote All ITR Floor Remote All ITRSS Counter Remote...
Page 19: ...19 All ITRSS Floor Remote Floor ITD ITDSS NON Refrigerated...