- 25 -
Case Install
The Inner Outer Duct Assemblies and Retainer Brackets are shipped attached to the case refrigeration
compartment. The Duct Assemblies and Retainer Brackets must be removed before setting case into
cabinet opening. To disassemble remove the (8) screws holding each Duct Assembly to the louvered panel
also remove the (2) screws holding each Retainer Bracket.
Lift handles and screws are shipped loose with case. To use the provided handles, remove the end glass
panels as described in the End Panel Installation section of this manual. There are holes provided in the side
rails of case in the location shown below. Attach handles using the provided 1/4-20 screws. Be sure to use
gloves to prevent injury and use handles to lift case into cabinet. Once case is placed into cabinet remove
the (4) handles and install side glass as described in End Panel Installation section of this manual.
Once case is in place it must be secured to prevent it from moving during use. Reattach the Retainer
Brackets that were previously removed in same location using the #8 hex head screws. Push bracket up
tight to bottom of counter top and tighten screws. Predrill (4) 5/32 holes ½” deep into the counter top. (Be
careful not to drill through top of counter)
Summary of Contents for ITD Series
Page 14: ...14 Counter ITR60 Self Contained Counter ITRSS60 Self Contained...
Page 15: ...15 Floor ITR ITRSS 36 Self Contained...
Page 16: ...16 Floor ITR ITRSS 48 Self Contained Floor ITR60 Self Contained...
Page 17: ...17 Floor ITRSS60 Self Contained Refrigerated Remote Models...
Page 18: ...18 All ITR Counter Remote All ITR Floor Remote All ITRSS Counter Remote...
Page 19: ...19 All ITRSS Floor Remote Floor ITD ITDSS NON Refrigerated...