- 45 -
Adjusting the set point
The set point is what determines how cold the display case will hold food and beverage. To adjust the set
point press and hold the
button approx. 5 seconds until the display begins to flash a number. Then
press the use the
button to scroll number up (colder) or press the
button to scroll number lower
(warmer). There are nine (9) available set points numbers, the higher the number of the set point, the
colder the display case will run, with setting “9” being the coldest and setting “1” being the warmest.
Once you have chosen your desired setting press the
button
again to confirm your choice.
Entering manual defrost mode
In order to initiate a manual, defrost press and hold the
button approx. 5 seconds. The control will
read “dEF” while the button is being held. The defrost is initiated when the defrost mode indicator
illuminates on the display. The control display will then return to reading the case temperature. When the
defrost mode indicator turns off the defrost is complete and the compressor will turn back on
illuminating the compressor run indicator .
Error codes
It is possible for error codes to be displayed on the control screen. In the event of a malfunction an alarm
will sound and the alarm indicator will be displayed on the display. An error code or codes will flash
intermittently on the display. If there are multiple codes, the display will continuously cycle through
them. The following photo shows error code “E0” as an example.
Mute:
You may mute the alarm by pressing and releasing the wrench button. The red ringing bell and all
error codes will still be displayed. When the fault is remedied the control will return to normal operation
and will automatically clear the codes from the display.
Summary of Contents for ITD Series
Page 14: ...14 Counter ITR60 Self Contained Counter ITRSS60 Self Contained...
Page 15: ...15 Floor ITR ITRSS 36 Self Contained...
Page 16: ...16 Floor ITR ITRSS 48 Self Contained Floor ITR60 Self Contained...
Page 17: ...17 Floor ITRSS60 Self Contained Refrigerated Remote Models...
Page 18: ...18 All ITR Counter Remote All ITR Floor Remote All ITRSS Counter Remote...
Page 19: ...19 All ITRSS Floor Remote Floor ITD ITDSS NON Refrigerated...