- 30 -
Joining Floor Model Bases (Single End Panels Between)
1.
cases are joined in the same manner as described in previous
Joining Cases section, but the bases will also need to be joined.
2.
Push cases together and align front and rear of cases.
3.
Push cases together and align front and rear of cases.
4.
Remove the base front and back panels as described in
Refrigeration Compartment Panel Removal
Section.
5.
Push cases together and align front and rear of cases and bases.
-If there is a miss-alignment between cases and the bases, it may be necessary to loosen the
screws holding the case to the base. The mounting brackets are located inside the top of the base
and there are (2) in the front and (2) in the back. This will allow slight adjustment to improve
alignment. Retighten these screws once components are properly aligned.
-It may also be necessary to adjust leg levelers under base until case fronts align and the base
side is tight together.
6.
Attach the Left case to right case using (7) 10-18 screws and washers provided. NOTE: The bases must
be placed tightly together. Do not try to pull cases together with screw or the panel will strip out.