LEVEL 4
2-7
GENERAL
LEVEL 4 is used to configure the siren
functions.
SIREN FUNCTION
The siren function is chosen by press-
ing key 17.
When key 17 is on, the siren keys
activate the siren tone only if the siren is
armed by one of the bottom row keys.
The sirens are dependent on the bot-
tom row.
When key 17 is off, the siren tones don’t
require the siren to be armed by the
bottom row, and will activate as soon as
pressed. They are independent of the
bottom row.
H/L and PRIORITY
DISABLE
If key 19 is on, then H/L will be nonfunc-
tional. If key 20 is on, then PRIORITY
will be nonfunctional.
HORN RING TRANSFER
TONE
The horn ring transfer tone is selected
by pressing key 18.
If key 18 is off, the tone will be YELP.
That is, when WAIL is the operating
tone and the Horn Ring is pressed and
transferred, the tone will transfer to
YELP.
If key 18 is on, the tone will be PRIOR-
ITY. That is, when WAIL, YELP, or H/L
is the operating tone and the Horn Ring
is pressed and transferred, the tone will
transfer to PRIORITY.
HORN RING - NO TONE
Press key 15 if you want Peak & Hold
from the Horn Ring when no sirens are
active. Press key 16 if you want Air
Horn from the Horn Ring when no si-
rens are active.
SIREN POWER-UP
Keys 10 through 14 can be configured
to turn on automatically during power-
up. Simply turn on the key(s) you wish
to be active when the system powers
up. (This is basically used to decide the
selected siren tone when Sirens are
configured to be dependent on the bot-
tom row.)
SIREN ENABLE
Siren enable, or Siren armed, keys are
used when sirens are to be dependent
on the bottom row for activation. Choose
which keys (5 through 8) you wish to
enable, or arm, the selected siren tone.
To enable sirens on the slide switch,
press key 9 until the desired slide
switches are chosen.
SAVE
Press the SAVE key when you have
LEVEL 4 configured the way you want.
This will return you to the MAIN MENU.