HPB
TM
Series
© Copyright 2018 Fluid Equipment Development Company | www.fedco-usa.com
-
12
-
Installation Procedures Continued
Installation Configurations
High Pressure Centrifugal Feed Pumps
• A throttle valve is needed to regulate feed pump discharge pressure.
•
The throttle valve should be located between the feed pump and the HPB feed inlet.
•
If the feed pump speed is controlled by a variable frequency drive (VFD), a throttle valve is
not required.
NOTES:
Minimum distance between high pressure pump and throttle valve is pipe dia x 3.
Figure 10 -
Centrifugal Feed Pump Configuration
Motor
Brine
Permeate
Product
High Pressure
Brine Stream
High Pressure
Location
Throttle Valve
Brine Outlet
Pump
Feed
High Pressure
HPB™