![FEDCO HPB-2800 Installation & Operation Manual Download Page 20](http://html1.mh-extra.com/html/fedco/hpb-2800/hpb-2800_installation-and-operation-manual_3784299020.webp)
HPB
TM
Series
© Copyright 2018 Fluid Equipment Development Company | www.fedco-usa.com
-
20
-
Basic Troubleshooting
If the booster does not operate properly, refer to the following troubleshooting charts as a guide
to determining the concern and identifying the potential cause. If after consulting the trouble
-
shooting charts the cause is still undefined, contact FEDCO technical support by e-mail
([email protected]), telephone or fax. FEDCO will give you easy, step by step instruc
-
tions on how to proceed.
Visual Inspection
• Make sure all items are accounted for on
the start up check list.
•
Inspect all high pressure booster piping.
•
Inspect the booster mountings for signs of
any movement or vibration.
• Inspect pressure gauges, switches and all
other instrumentation for proper operation.
•
Record any unusual readings.
Figure 23 -
HPB Basic Visual Inspection
Air Vented from System ?
Sufficient Output Pressure ?
Booster Leaking ?
Sufficient Input Pressure ?
Inlet Restrictions ?
Loose Mountings or
Signs of Movement ?
Discharge Restrictions ?
Inlet Piping Leaks ?