Installation Procedures Continued
Flanged Connections
•
Flange faces should be parallel 1/16 inch per foot diameter.
•
Flange bolt holes should be aligned with a maximum offset of 1/8”
•
Flange faces must be no more than a maximum of .5 degrees from each other.
• Take appropriate measures to compensate thermal expansion of the piping.
•
Measure and record the flange gaps in the
section of this manual.
Flanges Pipe Size
(in.)
Allowable Gap
(in.)
½
0.018
¾
0.020
1
0.022
1 ½
0.026
2
0.031
3
0.039
4
0.049
6
0.057
8
0.070
10
0.083
12
0.099
Figure 17 - Pipe Flange Fitting Allowable Gap
YES
NO
NO
Figure 18 - Proper Piping Alignment