FEASA LED ANALYSER
ICT VERSION
Capture Sequence Mode
GetFlicker## -
Returns the Flicker Index and frequency after a Seq Cap.
Transmit
Receive
getflicker##
xxx.x %, y.yyyyyy, fff.f Hz
Where:
##
represents the Fiber Number and is a value in the range 01 – 20.
xxx.x
represents the Flicker Duty Cycle in Percentage.
y.yyyyyy
represents the Flicker Index.
fff.f Hz
represents the Flicker Frequency in Hertz.
Description
This command reports the Flicker Duty Cycle, Flicker Index and Frequency of the Led under
test after the sequence capture is complete.
Example:
The PC transmits
getflicker01 t
o the LED Analyser to instruct it to report the Flicker Index
Frequency of fiber No.1
getflicker01
Flicker : 100.0% Flicker index: 0.283214 Flicker Frequency: 100.0 Hz