DEFIBRILLATOR MONITOR
Mod. 3850B-BIPHASIC - USER MANUAL
Page 2 of 63
NOTES AND WARNINGS
WARNING! The followings are descriptions of the general dangers and unsafe usage of the Defibrillator Monitor Mod 3850B-
Biphasic, which can lead to death or severe damage to the user or the equipment.
¾
You should read this manual before beginning installation and use of equipment.
¾
This equipment is meant to be used by persons trained in professional health care.
¾
Defibrillator Monitor Mod. 3850B-Biphasic use is limited to a single patient at a time.
¾
This equipment must be used in conjunction with signs and symptoms of the patient. The equipment is designed to be an aid in
clinical diagnosis.
¾
Do not reuse any element disposable or single use. The time limit of use thereof is that indicated by the manufacturer.
¾
The expiration date of this equipment is of 5 years from its purchase, when that time is over, dismiss the equipment and it’s
accessories following the local regulations in force.
¾
In case of discarding the equipment or one of its accessories, at the end of its useful life, do it according to the local regulations,
normative or laws in force.
¾
In order to take care of the environment, you can send the equipment to
feas
ELECTRÓNICA
for its disposal.
¾
RISK OF ELECTRICAL SHOCK, if you remove the equipment’s lead. Do not remove the equipment’s lead. Ask for assistance
from qualified and authorized personnel.
¾
There is a risk of Electrical Shock and death. Do not use this equipment if you doubt of the integrity of any cable. Check the cables
periodically (disconnect them before) to verify their integrity; paying special attention to cable points close to connectors and
paddles. In case you find an irregularity, request the part to our Customer’s Service.
¾
Do not touch the Power Line connectors with wet hands.
¾
The Defibrillator Monitor Mod 3850B-Biphasic is designed with covers and plastic handles to minimize the risk of electrical shock.
When it is not plugged to the line power its energy will be provided by the battery, without ground reference.
¾
The multi-outlet power extension cord shall not be placed on the floor.
¾
The multi-outlet power extension cord should only be used to power equipment that is part of the system.
¾
All combinations of medical equipment with non-medical equipment must comply with the total leakage current specified in IEC
60601-1, Cl. 16.
¾
When combined instruments, the sum of the leakage currents can be dangerous for both the patient and the operator. If you can’t
determine the leakage current of each team on the specifications of each, technical staff will take measurements to ensure the
installation complies with the requirements of EN 60601-1, Cl. 16. In any case, the user should consult the manufacturer to ensure
that the sum of leakage currents will not jeopardize patient safety.
¾
The device is intended to be connected to:
- Installations in medical rooms belonging to Groups 0, 1, 2a and 2b, according to AEA90364-7-710 (IEC 60364-7-710).
- Installations according to AEA90364-7-771, installations in buildings in general, to grounded outlets according to IRAM 2071.
- Mobile units, to the cigarette lighter connector of the vehicle.
¾
The equipment must be connected to an approved electrical installation that includes a correct grounding according to the local
legislation in force. Do not use adapters or replace the device’s original cables. If the plug does not match the installation, please
contact our Customer Service for the provision of a suitable cable.
¾
You must make sure that the AC outlet, to which you will plug the device, has a groundling and is in good condition.
¾
Do not connect this device to an outlet controlled by a switch on/off.
¾
Verify the AC voltage range matches the voltage at which the equipment is to be connected. If does not match, contact
feas
ELECTRÓNICA
’s Service Customer.
¾
Verify the AC frequency indicated on the back panel matches the AC frequency which the device is to be connected. If does not
match, contact
feas
ELECTRÓNICA
’s Service Customer. Do not use the device in those conditions. The ECG curve will be
affected by noise and will not be able to use SYNC mode.
¾
If you have any doubts about the integrity of the ground, either the cable or the installation of the building, use the device from the
internal battery. In case that the battery is discharge or damage, don't use the equipment.
¾
The disconnection of the equipment from the Power Line does not de-energize it, since it has an internal battery, so you must also
set the selector switch to OFF.
¾
Caution, leave one end of the power cord accessible so that in the event of an emergency, it is easy to disconnect the equipment
from the Power Line.
¾
Do not disconnect power by pulling the cord. Disconnect the connector firmly grasping.
¾
Do not excessively bend the plug or power cord or place heavy objects on them, which could cause damage.
¾
Do not immerse the electrical connector in liquids. This can damage the cable or connector by corrosion.
¾
RISK OF FIRE AND/OR EXPLOSION: do not use this equipment in the presence of flammable gases (anesthetics, oxygen, etc).
¾
Not use or store inflammable substances near the equipment.
¾
Avoid installing this equipment in places where liquids can be spilled on it. Avoid direct exposure to splatter, sprayer or air vented
from nebulizers or humidifiers.
¾
Do not place containers with water, chemicals or any small metal objects on the equipment.
¾
Do not use this equipment under the rain. You have to make sure that the equipment, the cables and paddles are dry before you
start using them.