![FBII XL-5 User Manual Download Page 20](http://html2.mh-extra.com/html/fbii/xl-5/xl-5_user-manual_3736424020.webp)
– 20 –
Bypass
Bypasses are performed to eliminate burglary zones that are not ready
or faulty from activating the Security System.
Bypass Procedure
BYPASS [USER] ZN
Depress the BYPASS key followed by your user code and the three
digit zone number (000 - 072) to be bypassed.
The zone number to be bypassed is shown as ZN. For example, if your
user code is 7356 and you want to bypass zone 16 enter:
BYPASS 7 3 5 6 0 1 6
Press the bypass key followed by 7 3 5 6 (your user code), and 0 1 6
(desired zone to be bypassed).
Multiple zones may be bypassed by repeating the sequence for the
desired zones within a fifteen-second time period as follows:
EXAMPLE:
BYPASS [USER] 002 BYPASS 056 BYPASS 071
The sequence displayed above would have bypassed zones 2, 56 and
71.
Zones can be bypassed if the user performing the bypass is authorized
to perform bypasses and the zone has been defined by your installer as
bypassable.
If the zone has already been bypassed, the sequence will unbypass the
zone except if the system is armed and the unbypassed zone is still not
ready. Unbypass means that the zone returns as an active burglary
zone.
After the bypass (or unbypass) command has been accepted the unit
will emit a continuous beep and keypads will display the bypassed
zones as follows: