Arming the System (cont)
TO BYPASS A ZONE
The Bypass function excludes a zone of protection from the security system
until it is unbypassed (either by using the unbypass procedure or when you
disarm the system). Bypassing can only be done while the system is disarmed.
NOTE: 24-hour zones may be bypassed, but can only be unbypassed if the zone
is not faulted (condition has been cleared).
Press the BYPASS button. Then enter your user code and the zone number to
be bypassed, as follows:
BYPASS
followed by your user code
†
+
Zone No
.
†
If the Quick Bypass feature has been enabled by the installer, do not enter the
user code when bypassing zones.
NOTE:
Bypassed zones are NOT protected when the system is armed. After
the bypass command has been accepted, the keypad sounds one long beep, and
the following is displayed:
LCD Keypad:
BYPASSED: ZN 01
FRONT DOOR
Fixed-Word Keypad:
BYPASS
Zone number displayed
LED Keypad:
Zone LEDs of the
zone(s) bypassed slowly
blink
To Bypass multiple zones, within 10 seconds of the User Code +
Zone No. entry, enter:
BYPASS
+ Zone No.
This command can be repeated for each zone to be bypassed.
TO UNBYPASS A ZONE
Pressing the BYPASS button returns a bypassed zone to normal operation. To
unbypass a zone, the system must be disarmed. (Also note that 24-hour zones
cannot be unbypassed if they are faulted.) To unbypass a zone(s), repeat the
bypass function as follows:
BYPASS
followed by your user code
†
+
Zone No.
†
If the Quick Bypass feature has been enabled by the installer, do not enter the
user code when unbypassing zones.
After unbypassing, the zone display will show the state of the zones.