Maintenance measures - 500 h
4812159901_D.pdf
2023-01-25
Air conditioning (Optional)
- Inspection
Fig. Air conditioning
1. Refrigerant hoses
2. Condensor element
3. Drying filter
2
3
1
Inspect refrigerant hoses and connections and make
sure that there are no signs of an oil film that can
indicate a refrigerant leakage.
If there is a signifcant loss of cooling capacity, clean
the condensor element (2) on the rear edge of the cab
roof.
Air conditioning (Optional)
Drying filter - Inspection
With the unit in operation, check using the sight glass
(1) that bubbles are not visible on the drying filter.
Figure. Drying filter
1. Sight glass
2. Filter holder
1
2
Park the roller on a level surface, chock the wheels
and activate the parking brake.
Park the roller on a level surface, chock the wheels
and activate the parking brake.
The filter is placed at the top of the rear part of the cab
roof.
If bubbles are visible through the sight glass, this
indicates that the refrigerant level is too low. Stop the
unit to avoid risking damage. Fill up with refrigerant.
The refrigerant circuit is only to be worked on by
authorized companies.
The refrigerant circuit is only to be worked on by
authorized companies.
132
Summary of Contents for DYNAPAC CC234C
Page 2: ......
Page 13: ...4812159901_D pdf 2023 01 25 1...
Page 14: ...4812159901_D pdf 2023 01 25 2...
Page 18: ...Introduction 4812159901_D pdf 2023 01 25 6...
Page 28: ...Special instructions 4812159901_D pdf 2023 01 25 16...
Page 74: ...Machine description 4812159901_D pdf 2023 01 25 62...
Page 94: ...Operation 4812159901_D pdf 2023 01 25 82...
Page 108: ...Preventive maintenance 4812159901_D pdf 2023 01 25 96...
Page 128: ...Maintenance 10h 4812159901_D pdf 2023 01 25 116...
Page 132: ...Maintenance 50h 4812159901_D pdf 2023 01 25 120...
Page 146: ...Maintenance measures 500 h 4812159901_D pdf 2023 01 25 134...
Page 173: ......
Page 174: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...