Maintenance, 10h
4812159901_D.pdf
2023-01-25
Emergency watering (Accessory) - Extra pump
in pump system
1
Figure. Panel on right side of front
frame
1. Extra pump
If the water pump stops, an extra pump will keep the
sprinkler system in operation.
Connect the electric cable and water hoses to the
extra pump instead of the standard pump.
The water hoses are connected to the pump with quick
couplings to simplify draining and where appropriate
replacement to a reserve pump (option).
Newer machines can have sprinkler systems with dual
sprinkler pipes and sprinkler pumps as standard.
Sprinkler system/Wheels - Freeze risk
Fig. Wheel rack
1. Rear water tank
2. Sprinkler nozzle
3. Sprinkler system
1
3
2
Preventive measures when there is a risk of freezing.
Draining the system.
• Close the valve
• Separate the hose
• Open the coarse filter
• Loosen the intake to the pump by moving the plastic
clamp to the left and pulling the white plastic adapter from
the pump housing.
• Open the valves in the ends of the sprinkler ramps.
• Allow the fluid to run out and run the sprinkler pump for
about 10 seconds.
110
Summary of Contents for DYNAPAC CC234C
Page 2: ......
Page 13: ...4812159901_D pdf 2023 01 25 1...
Page 14: ...4812159901_D pdf 2023 01 25 2...
Page 18: ...Introduction 4812159901_D pdf 2023 01 25 6...
Page 28: ...Special instructions 4812159901_D pdf 2023 01 25 16...
Page 74: ...Machine description 4812159901_D pdf 2023 01 25 62...
Page 94: ...Operation 4812159901_D pdf 2023 01 25 82...
Page 108: ...Preventive maintenance 4812159901_D pdf 2023 01 25 96...
Page 128: ...Maintenance 10h 4812159901_D pdf 2023 01 25 116...
Page 132: ...Maintenance 50h 4812159901_D pdf 2023 01 25 120...
Page 146: ...Maintenance measures 500 h 4812159901_D pdf 2023 01 25 134...
Page 173: ......
Page 174: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...