3.4.2 Stepper Motor Mode
In stepper motor mode
stepmod
only a single input source is used, AUXin, which is connected
with
sor 2
.
If
sor 0
or
sor 1
are used, the drive will not receive a signal and will remain stationary.
Note that if a pulse train is applied to AUXin when operating in these modes the internal
counter will continue operating. If the input is then switched to AUXin via
sor 2
, the accumu-
lated pulse-count will be processed and the drive will be activated immediately.
3.4.3 Pointer Mode
Pointer Mode is selected by the command
ptrmod
, in which the rotor angle of the drive is
maintained proportional to a voltage input to AUXin (
sor 2
) or alternatively to the position of
the potentiometer “velocity 1“ (
sor 1
).
15
C
ommand
Function
Description
sor
Source
2 = AUXin is used as input
1 = Analog input (pot.) is used as input
0 = All external inputs will be ignored
stepmod
Stepper Motor Mode
Stepper motor with position preset
ptrmod
Pointer Mode
Instrument pointer mode
gmode
Get Mode
Display the selected mode in plain text