Table 3-4: Setting the load type connection
Digital output mode
Connection type setting
Output
Two-wire
Single-wire
Single-wire
with an external power
supply source
+Vout
0
OFF
XP1[3-4]
XP1[1-2] & XP1[3-4] & XP9
[1-2]
1
OFF
XP2[3-4]
XP2[1-2] & XP2[3-4] &
XP9[1-2]
2
OFF
XP3[3-4]
XP3[1-2] & XP3[3-4] &
XP9[1-2]
3
OFF
XP4[3-4]
XP4[1-2] & XP4[3-4] &
XP9[1-2]
4
OFF
XP5[3-4]
XP5[1-2] & XP5[3-4] &
XP9[1-2]
5
OFF
XP6[3-4]
XP6[1-2] & XP6[3-4] &
XP9[1-2]
6
OFF
XP7[3-4]
XP7[1-2] & XP7[3-4] &
XP9[1-2]
7
OFF
XP8[3-4]
XP8[1-2] & XP8[3-4] &
XP9[1-2]
Warning!
In case of the load single-wire connection, it should be considered that
despite the fact that each module's channel is able to switch currents with the
load up to 500 mA, total current, returnable via GND_VOUT contacts, should
not exceed the values 4А (2A per each GND_VOUT contact).