User Manual
DIC324
Table 3-1: SA1 switch setting
Base
Base
address (Hex)
address
(Hex) SA1-8 = 1
SA1-8 = 0
SA1-
6
(BA5)
SA1-
5
(BA4)
SA1-
4
(BA3)
SA1-
3
(BA2)
SA1-
2
(BA1)
SA1-1
(BA0)
000h
A000h
0
0
0
0
0
0
010h
A010h
0
0
0
0
0
1
…
…
…
…
…
…
…
…
100h
A100h
0
1
0
0
0
0
110h
A110h
0
1
0
0
0
1
…
…
…
…
…
…
…
…
150h
A150h
0
1
0
1
0
1
…
…
…
…
…
…
…
…
200h
A200h
1
0
0
0
0
0
…
…
…
…
…
…
…
…
3E0h
A3E0h
1
1
1
1
1
0
3F0h
A3F0h
1
1
1
1
1
1
ATTENTION:
INCORRECT SETTING OF THE BASE ADDRESS COULD CAUSE COLLISIONS
DURING MODULE'S OPERATION WITH SYSTEM'S EQUIPMENT. PRIOR
TO THE FIRST MODULE ACTIVATION YOU NEED TO MAKE SURE THAT
THE SET BASE ADDRESS IS NOT USED WITHIN THE SYSTEM!
3.2.2
Jumpers for the installation of input signal connection type
Signals are connected to the DIC324 Module via XP10 connector (type IDC-34).
Connection types:
1. Single-wire connection of digital signals
2. Two-wire connection of digital signals
3. Two-wire connection of potential-free contacts
4. Single-wire connection of potential-free contacts
29