-76-
8.5 Setting the operation data
8 types of operation data can be set in this product.
Operate by selecting the operation data number using the P0, P1 and P2 input signals.
Operation mode : Data mode
Item
Display
Setting range
Factory setting
Operation
data
number 0~7
Rotation speed
sPd0 ~
sPd7
50 ~ 4000 r/min
100
Acceleration time tA0 ~ tA7
0.0 ~ 15.0 sec
0.5
Deceleration time td0 ~ td7
Torque limit
tq0 ~ tq7
10~ 300 %
300
Initialize
Ini0 ~ ini7
Restores the operation data to the factory
setting.
Initialize each operation data
number.
-
Refer to the next page for detail about the acceleration time and deceleration time.
Rotation speed
Acceleration time
Deceleration time
Time