-58-
• Precaution of “External operation signal input” parameter setting
“Wn.oP” warning generates when I/O Enable is ON after I/O activated when “I/O Enable” is OFF
status.
Set the "External operation signal input" parameter of the drive while I / O connection is
stopped.
• Timing chart example
In case of parameter “external operation signal input” to “on” and the rotation direction switch is
set to “FWD”.
※ Operation input
• The motor rotates when either FWD input or REV input is set to “ON”.
• The motor instantaneous stop when FWD input and REV input is set to “ON” at the same time.
7.5.2 Operating with multiple speeds
The operation at a speed of two or more can be performed by swiching the external input.
Up to 8 speeds can be performed.
Summary of Contents for Ezi-SPEED ESD-120-C