-60-
• Operating method
Operate the motor by selecting any of the operation data No.0 to No.7 based in a combination of
ON/OFF status of the P0, P1 and P2 inputs. The motor is operated using the rotation speed,
acceleration time, deceleration time and torque limit in the selected operation data number.
• Operation procedure (When the “external operation signal input” parameter is set
to “ON”)
1. Set the operation switch to “RUN” side
2. Select the operation data number suing the P0, P1 and P2 inputs
3. When the FWD or REV input is turned ON, the motor will rotate.
4. Switch the operation data number using the P0, P1, and P2 inputs
5. When the FWD or REV input switch has been turned ON or is turned OFF, the motor will
stop.
Operation data number
P0
P1
P2
Rotation speed [rpm]
0
OFF
OFF
OFF
1000
1
ON
OFF
OFF
500
2
OFF
ON
OFF
2000
3
ON
ON
OFF
1500
4
OFF
OFF
ON
3000
5
ON
OFF
ON
2500
6
OFF
ON
ON
4000
7
ON
ON
ON
3500
* Setting speed value is example, can be changed to needed speed.
When changing from the present speed to the new speed, the acceleration time and deceleration
time set in the next operation data number are used.
Summary of Contents for Ezi-SPEED ESD-120-C
Page 1: ......
Page 9: ...9 2 Characteristics 2 1 Part number...
Page 15: ...15 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Page 18: ...18 ESM 90 H 120 ESM 104 H 200 ESM 104 H 400...
Page 19: ...19 4 3 Characteristics of motor torque 30W 60W 120W...
Page 20: ...20 200W 400W...
Page 63: ...63 8 2 Setting and 7 segments display 1 Monitor mode...
Page 64: ...64 2 Input Output setting mode...
Page 65: ...65 3 Parameter setting mode 1page...
Page 66: ...66 3 Parameter setting mode 2page...
Page 67: ...67 3 Parameter setting mode 3page...
Page 68: ...68 3 Parameter setting mode 4page...
Page 69: ...69 4 NVM saving mode...