OPERATING AND MAINTENANCE MANUAL
RASE.TOP.4028
Code DOC.
UM TOP AUTOMATIC
4.0
Rev. 6
Page 33 of 86
33
c) Finishing work and floors
No special finishing work is required for installation. Unless indicated otherwise, the floor must
support a specific load of 2 kg/cm
2
and be of the industrial type, smooth and flat.
d) Power supply lines
The connection points on the machine to the power and pneumatic supply lines are located on the
lower back part of the machine (Fig. 19). The power supply and pneumatic networks at the
customer's premises are to have the following characteristics:
Electrical energy: voltage = 230 V, frequency = 50/60 Hz, single phase power supply with
overload conductor.
Compressed air: dry, pressure between 6 to 9 bar.
Figure 19 – Connection points to power sources
The ambient conditions for proper use of the machine are indicated in Table 2:
Parameter
Values allowed
Operating temperature (ambient)
from -5° C to + 40 °C
Daily average temperature
< 40 °C
Storing temperature
from -10 °C to +50 °C
Relative humidity in the absence of
condensation
from 30% to 95%
Table 2 – Ambient conditions for proper use of the machine