GROWSPAN
™
ROUND PRO GREENHOUSES AND SYSTEMS
24
Revision date: 01.03.19
END PANEL INSTALLATION (continued)
Cut upper panel
to proper length.
Photo shows removal of panel using a power tool
equipped with a round cutting bit. (Greenhouse shown
is used for illustration only. It is of a different model.)
ATTENTION:
Review roof panel installation steps to
determine how to finish joint between end panels and
roof cladding.
Cut panels as installed, or after all are
installed (if weather and wind conditions allow).
7. Continue to prepare and install panels and aluminum
profile in the locations shown on end panel diagrams
(Quick Start section) to complete lower row of panels.
104213 U-profile here along door edge.
A
B
6' x 10'
6' x 10'
9. After cutting panels, attach 104213 profile to upper (or
outer) edge of all panels.
See dashed line in diagram
under previous step for profile location.
NOTE:
To bend U-profile (104213), prepare as shown:
a. Cut angled notches from profile to allow bending.
b. Distance between notches is determined by degree
of bend.
c. Bend U-channel profile at notches before installing.
10. Repeat procedures to install panels for remaining end
wall.
Review Quick Start diagrams for layout.
11. Continue with
Double Door Assembly
procedures.
8. Prepare and install upper panels. Cut upper edge of
panel to correct length using rafter profile as a guide.
Do not apply vent tape of any upper panel edge.
Attach 104213 U-profile to bottom of panels above door.