31
DRYING TABLES — C-21100B
The above drying capacities are estimates based on drying principles, field results, and computer simulations. Variances may occur
due to the grain’s physiological factors (kernel size, chemical composition, variety, maturity), escessive fines, weather conditions, etc.
CORN ...dry & cool
190 °F
210 °F
230 °F
% Unload
Dry
Capacity
% Unload
Dry
Capacity
% Unload
Dry
Capacity
in
out
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
17
15
74
18
1914
85
16
2187
18
15
56
24
1443
64
21
1649
19
15
45
30
1176
52
26
1344
58
23
1512
20
15
39
35
999
44
31
1142
50
27
1285
21
15
34
40
869
38
35
993
43
31
1117
22
15
30
46
765
34
40
875
38
35
984
23
15
26
51
679
30
45
777
34
40
874
24
15
23
58
606
27
50
693
30
45
779
25
15
21
64
542
24
56
619
27
50
697
26
15
19
72
486
21
63
555
24
56
625
27
15
17
80
437
19
70
499
22
62
561
28
15
15
89
393
17
78
449
20
69
505
29
15
14
98
355
16
86
406
18
76
457
30
15
12
108
322
14
95
368
16
84
414
31
15
11
119
293
13
104
335
15
93
377
32
15
10
130
268
12
114
306
13
101
345
33
15
10
142
246
11
124
282
12
110
317
34
15
9
153
228
10
134
260
11
119
293
35
15
8
165
212
9
144
242
11
128
272
CORN ...full heat
190 °F
210 °F
230 °F
% Unload
Dry
Capacity
% Unload
Dry
Capacity
% Unload
Dry
Capacity
in
*out
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
18
17
88
23
2269
100
20
2593
19
17
71
28
1846
82
25
2110
92
22
2374
20
17
61
33
1572
69
29
1797
78
26
2021
21
17
53
38
1371
61
33
1567
68
30
1763
22
17
47
43
1212
54
38
1385
60
34
1558
23
17
42
49
1077
48
43
1231
54
38
1385
24
17
37
54
961
42
48
1099
48
42
1236
25
17
33
61
859
38
53
982
43
47
1104
26
17
30
68
769
34
60
878
38
53
988
27
17
27
76
689
30
67
787
34
59
886
28
17
24
85
619
27
74
707
31
66
796
29
17
22
94
558
25
82
638
28
73
717
30
17
20
104
505
22
91
577
25
81
649
31
17
18
114
459
20
100
525
23
89
590
32
17
16
125
420
19
109
480
21
97
540
33
17
15
135
387
17
118
442
19
105
497
34
17
14
146
359
16
128
410
18
114
461
35
17
13
156
335
15
137
383
17
121
431
*represents the target moisture out of the dryer. Expected final moisture in the bin is 15.0%
Based on 100% Unload rate of
2585 bph
MOISTURE
MOISTURE
Summary of Contents for C-21100B
Page 22: ...20 ...
Page 36: ...34 Fig 6 3 LP vaporizer assembly Fig 6 4 ASC control panel ...
Page 49: ...Fig 8 1 Power circuit 220V 3 PH for C 2130B C 2140B C 2160B only 47 4B0280A TIF ...
Page 50: ...48 Fig 8 2 Power cirucit 220V Part wind start for C 2175B C 21100 models only 4B0280C TIF ...
Page 51: ...49 Fig 8 3 Power circuit 440V 3 PH for all C 2100B models 4B0280B TIF ...
Page 52: ...Fig 8 4 Control circuit all models except part wind start p 1 of 3 50 4B0280D TIF ...
Page 53: ...Fig 8 4 Control circuit all models except part wind start p 2 of 3 51 4B0280E TIF ...
Page 55: ...Fig 8 5 Control circuit part wind start models only p 1 of 3 53 4B0280H TIF ...
Page 56: ...Fig 8 5 Control circuit part wind start models only p 2 of 3 54 4B0280I TIF ...
Page 58: ...Fig 8 6 Safety circuit portion of control circuit all models 56 4B0280G TIF ...
Page 65: ......