9  FACTORY SETTINGS 

Name Factory  Description 

Page

 settings

#0 

“Location” 

SMS  main head text

 26

#1 

“Input 1” 

SMS input 1 text

  

26

#2 

“Input 2” 

SMS input 2 text 

26

ADF 

Auto dial functionality to TN1 

 

25

ALC 

Automatic log clear

 32

ARST 

Period of time for automatic reset 

 24

BUZ 

Buzzer control  

25

BMOD

  1 

Single or double buttons operation 

14

CC1 

Empty  

Check credit, universal provider  

22

CC2 

Empty  

Check credit, TIM Italy  

22

CC3 

Empty 

 

Check credit, Vodafone Italy

 22

CLP1 

Empty 

 1

st

 

CLIP number

 30

CLP100 

Empty 

 100

th

 

CLIP number

 30

CLPCRL  

Delete all CLIP numbers  

33

CLPEN 

Enable CLIP functionality

 30

CLPI 

CLIP activation conditions

 30

CLPOU 

Output activated by CLIP function

 30

CREF 

“EUR” 

Parse text (CC1 operator) 

 23

CTIM 

“EURO” 

Parse text (CC2 operator)

 23

CVODA 

“E’.” 

Parse text (CC3 operator)

 23

DD1 

Input 1 delay before dialing

 16

DD2 

Input 2 delay before dialing

  

16

EVIN 

Alarm storing on LOG list                               32

HTN 

Hidden telephone number of device

 24

ID1 

Input 1 length of pulse 

 16

ID2 

Input 2 length of pulse 

 16

IN1 

Operating mode input 1 

 

15

IN2 

Operating mode input 2 

 

15

INS  

Prints status of the inputs

 36

KPA

x

 

Empty 

 

Calling button

 x, 1

st

 telephone number 

27

KPB

x

 

Empty 

 

Calling button

 x, 2

nd

 telephone number 

27

KPC

x

 

Empty 

 

Calling button

 x, 3

rd

 telephone number 

27

KPT

x

 

25 

Calling button

 x, 

calling time  

 27

LCLR  

Clear the list of events 

33

LCV 

Low credit value 

 22

LN1 

Empty 

 

Input 1, link to telephone numbers 

 17

LN2 

Empty 

 

Input 2, link to telephone numbers

 17

LN3 

Empty 

 

Periodic SMS text, link to phone numbers 

17

LN4 

Empty 

 

SIM card refill, link to telephone numbers

 17

LN5 

Empty 

 

NAC, link to telephone numbers

 17

LN6 

Empty 

 

LOG full, link to telephone numbers

 17

LNG 

Language selection

 

25

LOGI 

Log interface

 32

LOGN 

Number of  log events for printing out

 32

LOT 

60 

Max conversation time 

 17

MIC 

22 

Microphone  sensitivity setting

 (0 ÷ 40) 

24

MNF 

Empty 

 

Manual/auto selection of 3G provider

 24

MRES  

Manual restart 3G Cinterionmodule

 33

MUT 

Mute functionality

 

25

9  PROGRAMMAZIONI DI FABBRICA

Nome  Valore di  Descrizione 

Pagina

 fabbrica

#0 

“Luogo” 

Testo principale SMS di allarme 

26

#1 

“Ingresso 1” Testo SMS allarme dell'ingresso 1  

26

#2 

“Ingresso 2” Testo SMS allarme dell'ingresso 2 

26

ADF 

Chiamata automatica a TN1 in giorni  

25

ALC 

Cancellazione automatica memoria (Log) 

32

ARST 

Periodo di tempo del riavvio automatico 

24

BUZ 

Controllo del buzzer  

25

BMOD

  1 

Modalità tasto singolo o doppio 

14

CC1 

Vuoto 

Controllo credito residuo, operatore generico  22

CC2 

Vuoto 

Controllo del credito residuo, TIM Italia  

22

CC3 

Vuoto 

Controllo del credito residuo, Vodafone Italia 22

CLP1 

Vuoto 

1° numero funzione CLIP 

30

CLP100 

Vuoto 

100° numero funzione CLIP 

30

CLPCRL  

Cancella tutti i numeri CLIP 

33

CLPEN 

Attivazione funzione CLIP   

30

CLPI 

Condizione di attivazione dell'evento CLIP  30

CLPOU 

Controllo pin d'uscita con evento CLIP 

30

CREF 

“EUR” 

Testo per estrarre il credito; operatore CC1  23

CTIM 

“EURO” 

Testo per estrarre il credito; operatore CC2  23

CVODA 

“E’.” 

Testo per estrarre il credito; operatore CC3  23

DD1 

Ritardo segnalazione allarme ingresso 1 

16

DD2 

Ritardo segnalazione allarme ingresso 2  

16

EVIN 

Memorizzazione allarmi nella lista eventi        32

HTN 

Nasconde il numero telefonico del dispositivo 24

ID1 

Durata impulso per allarme ingresso 1  

16

ID2 

Durata impulso per allarme ingresso 2  

16

IN1 

Modalità di funzionamento ingresso 1 

15

IN2 

Modalità di funzionamento ingresso 2 

15

INS  

Stampa lo stato degli ingressi 

36

KPA

X

 

Vuoto 

Pulsante di chiamata x, 1° numero telefonico  27

KPB

X

 

Vuoto 

Pulsante di chiamata x, 2° numero telefonico  27

KPC

X

 

Vuoto 

Pulsante di chiamata x, 3° numero telefonico  27

KPT

X

 

25 

Pulsante di chiamata x, tempo di risposta 

27

LCLR  

Cancella la lista degli eventi 

33

LCV 

Limite credito residuo 

22

LN1 

Vuoto 

Ingresso 1 collegato ai numeri telefonici 

17

LN2 

Vuoto 

Ingresso 2 collegato ai numeri telefonici 

17

LN3 

Vuoto 

Numeri telefonici per invio SMS test periodici  17

LN4 

Vuoto 

Numeri telefonici per invio SMS stato SIM  17

LN5 

Vuoto 

Numeri telefonici per invio SMS eventi NAC  17

LN6 

Vuoto 

Numeri tel. per invio SMS lista eventi piena  17

LNG 

Selezione della lingua 

25

LOGI 

Supporto memorizzazione eventi 

32

LOGN 

Numero di eventi inviati alla stampa 

32

LOT 

60 

Durata massima della conversazione 

17

MIC 

22 

Regolazione sensibilità microfono (0 ÷ 40)  24

MNF 

Vuoto 

Selezione manuale/autom. del gestore 3G  24

MRES  

Riavvio manuale del modulo 3G Cinterion  33

MUT 

Abilita/disabilita il tono di chiamata 

25

Summary of Contents for Alba AB3G

Page 1: ...ogy that is designed to ensure a reliable and simple intercom application It is designed for wireless intercom system or access control system In addition AB3G module supports 2 inputs for analog comm...

Page 2: ...o quando acceso L esecuzione dell impianto deve essere effettuato da per sonale specializzato ed in conformit con le leggi vigenti In caso di guasto funzionamento irregolare o modifica all impianto av...

Page 3: ...anto attivando l interruttore generale del sistema Programmare il modulo AB3G Completare l installazione delle parti meccaniche tasti copri sede cornice ecc figura 7a e 7b 2 INSTALLATION 2 1 PUSH BUTT...

Page 4: ...4 Mi 2546 Italiano English 1 2 Fig 2b Fig 3 Fig 4 Fig 5a Fig 5b Fig 5c click click ART EC733 Fig 2a AB71 AB72 AB73...

Page 5: ...5 Mi 2546 Italiano English Fig 7a 3 1 2 SILICONE Fig 7b Abcde Mnop click click A bcde M nop Fig 6 A bcde M nop OK A bcde M nop A bcde M nop AB71 AB72 AB73 AB20 AB61 AB62 AB63 AB21...

Page 6: ...cessiva figura 10c Scollegare i cavi che collegano i moduli tra di loro figura 11 Smontare i moduli figura 12a 12b e 12c 2 2 REMOVING MODULES To disassemble the modules follow the instructions below s...

Page 7: ...7 Mi 2546 Italiano English Fig 10a Fig 10b Fig 10c Fig 11 Fig 12b 1 2 3 Fig 12a 1 4 5 3 A bcde M nop 2 3 1 A bcde M nop 2 4 5 Fig 12c AB20 AB21...

Page 8: ...0mA Consumo di corrente a riposo 80mA Modulo 3G Cinterion EHS6 A Antenna Integrata Ingressi 2 Uscite rel 2 24Vca cc 1Amax Temperatura di funzionamento 0 50 C Massima umidit ammissibile 90 RH 2 3 TECHN...

Page 9: ...tilizzare il cavo art EC733 come riportato in figura 3 1 2 5 6 7 8 13 14 15 16 3 4 9 10 11 12 17 18 19 20 27 26 25 28 33 34 35 36 41 42 43 44 40 39 38 37 32 31 30 29 24 23 22 21 51 50 49 52 57 58 59 6...

Page 10: ...rprogrammingthemoduleAB3G seeparagraph 4 Operation 6 3 Output Management 6 3 3 Controlling Outputs with DTMF 6 8 Intercom Functions c Schema installativo con 8 moduli tasti aggiuntivi CT2138AB c Insta...

Page 11: ...e 3G network 3 AVVIO IMPORTANTE PrimadiutilizzarelaschedaSIMneldispositivo inserirla nel proprio telefono cellulare e disabilitare la richiesta del codice PIN Se la scheda protetta dal codice PIN non...

Page 12: ...r lock is connected to the output 1 press within 2 seconds twice the key 1 number 11 3 1 CANCELLARE TUTTI I DATI PROGRAMMATI NELLA SCHEDA SIM Questa operazione necessaria se la scheda SIM che si inten...

Page 13: ...ccessivi paragrafi Programmazione con Personal Computer possibile programmare il dispositivo AB3G con un PC collegato tramite porta USB ed usando il software mycom manager Il programma pu essere scari...

Page 14: ...y inserting before the Country code i e 39340 44122 6 1 SINGLE OR DOUBLE BUTTON OPERATING MODE TheAB3GmoduleandthebuttonmodulesCT2138connected toitcanoperateeitherasasinglebuttonorasadoublebuttons 6 1...

Page 15: ...tivatosia chiudendol ingressopresceltoversomassa GND siaaprendo un circuito che normalmente chiude il morsetto d ingresso verso massa interruzione Loop di corrente Quando un ingresso rivela una condiz...

Page 16: ...e allarme ingresso 1 DD2 Ritardo acquisizione allarme ingresso 2 Table 2 Meaning of the parameters IN ID and DD Name Description IN1 Operating mode for input 1 IN2 Operating mode for input 2 ID1 Pulse...

Page 17: ...NE REMOTA DI UN EVENTO DI ALLARME I parametri seguenti sono utilizzati per definire le modalit con le quali il dispositivo AB3G segnala l evento di allarme Nota Il dispositivo AB3G invia messaggi SMS...

Page 18: ...t NAC occurs Telephone number responsible for this event could be sent via SMS to TN administrators for notification LN5 parameter Tabella 3 Parametri di segnalazione per gli allarmi Nome Descrizione...

Page 19: ...unzionamenti diversi come riportato nella tabella seguente OSx 0 Uscita x disabilitata OSx 1 Funzionamento bistabile modalit ON OFF OSx y Funzionamento monostabile modalit ad impulso dove y laduratade...

Page 20: ...5 DTMF control Number Description 00 Deactivate ALL outputs 01 Activate ALL outputs 10 Deactivate output 1 11 Activate output 1 20 Deactivate output 2 21 Activate output 2 6 3 2 Parametro ODx y Ilpara...

Page 21: ...e TN5 Nota Se SL 0 l accesso al dispositivo AB3G possibile da qualsiasi telefono IMPORTANTE se il parametroSLnon programmato ildispositivoaccetta TUTTElechiamate Daqualsiasitelefono possibile ilcontr...

Page 22: ...ori che prevedano per le informazioni sul credito l invio di stringhe anzich la chiamata ad un numero predefinito CC2 Questo parametro programmato con il numero del gestore Italiano di telefonia mobil...

Page 23: ...brica per la loro modifica chiedere al servizio clienti FARFISA 6 5 1 3 CREF CTIM CVODA parameters Parameters are used to find the credit value of the prepaid SIM card Strings under these parameters a...

Page 24: ...x x 0 minimo 20 massimo consente di modificare il livello di amplificazione dell altoparlante 6 6 8 Parametro ARST x Il parametro ARST x x 0 9999 definisce il periodo di tempo in ore dopo il quale ef...

Page 25: ...r ADF x parameter x 1 365 fix the period in days after which thedevicewillcallautomaticallytheadministratorTN1defined in paragraph 6 2 2 1 This feature is normally used to avoid that the GSM provider...

Page 26: ...It is possible to send an SMS message any time an alarm event occurs Default message is in English but language can be changed by LNG parameter Each message is composed of 3 parts and the user can wri...

Page 27: ...mbers maximum 6 8 1 KPAx KPBx KPCx parameters In these parameters should be stored the 3 phone numbers which refer to the same x calling button x x 1 200 6 8 2 KPTx parameter This parameter sets the r...

Page 28: ...8 19 20 KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC 51 50 49 52 57 58 59 60 65 66 67 68 KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC KPABC...

Page 29: ...ade button support is a user option to add an additional button to provide direct button pressed activation of the selected output for example opening the pedestrian gate 6 9 1 OD1 y OD2 y parameters...

Page 30: ...grado di operare sui rel di uscita utilizzando la funzionalit CLIP nel caso in cui i telefoni i cui numeri non sono memorizzati nei parametri CLIP1 CLIP200 o nei parametri KPA KPB e KPC chiamino il d...

Page 31: ...number Esempio Parametri CLIP Param Valore Descrizione CLPEN 1 Abilita la funzionalit CLIP CLPOU 2 Uscita 2 attivata con la funzione CLIP CLPI 0 Nessuna condizione d ingresso per l attivazione CLP1 04...

Page 32: ...li eventi ALC Modalit di cancellazione degli eventi 6 11 EVENT LOGGING AB3G module supports logging of specific events AB3G module logs CLIP door opening commands received from input 1 or 2 and alarm...

Page 33: ...i della SIM LCRL Cancella la lista eventi dal dispositivo AB3G CLPCRL Cancellanumeriedimpostazionidellafunzione CLIP MRES Ripristino manuale del modulo 3G Cinterion SSRES Ripristino manuale del dispos...

Page 34: ...quisizione di un allarme programmato nelle memorie DD1 DD2 PDD 7 10Livellodisicurezzaperl accessoaldispositivo PSL Inviando questo comando si riceve un messaggio SMS di risposta con il livello di sicu...

Page 35: ...e x gruppo iniziale y gruppo finale Esempio PKP 1 10 stampa i parametri dei primi 10 gruppi di utenti 7 17 Parametri speciali PSPEC Inviando questo comando si riceve un messaggio SMS di risposta con l...

Page 36: ...aldispositivoAB3G il numero di eventi registrati dipende dal valore impostato nel parametro LOGN vedi paragrafo 6 11 1 PLOG Attenzione i messaggi SMS di risposta a questo comando possono essere numero...

Page 37: ...OS2 1 ID1 120 LN1 1 In pochi secondi si ricever un messaggio SMS di risposta Se la procedura stata eseguita correttamente il messaggio SMSdirispostaconterr esattamenteglistessicomandiinviati 8 CHANGIN...

Page 38: ...SMS allarme dell ingresso 1 26 2 Ingresso 2 Testo SMS allarme dell ingresso 2 26 ADF 0 Chiamata automatica a TN1 in giorni 25 ALC 1 Cancellazione automatica memoria Log 32 ARST 0 Periodo di tempo del...

Page 39: ...odule 24 Nome Valore di Descrizione Pagina fabbrica OD1 1 Ingresso 1 collegato all uscita 1 o 2 29 OD2 2 Ingresso 2 collegato all uscita 1 o 2 29 OD3 0 Evento NAC collegato all uscita 1 o 2 16 29 OD4...

Page 40: ...irective 2012 19 EU WEEE RAEE Smaltire il dispositivo secondo quanto prescritto dalle norme per la tutela dell ambiente Dispose of the device in accordance with environmental regulations couler le dis...