13
GB
Revisione - 02
Date 03-2016
RAC 185
RAC 185
RAC 185
B
B
27 mm
RAC 185
B
16 mm
M
P
RAC 185
A
A
12 mm
0
I
WARNING!
Disconnect air feed when performing those
operations.
MAINTENANCE AND CHANGE OF SIZE
(fig.
f3-f4-f5
)
As a result of extended use of the riveting tool, the clamps may
slip on the nail due to deposited impurities.
It will therefore be necessary to clean and then lubricate the
clamps; if they are worn to such a degree as to impair operating
efficiency they must be replaced.
Remove the sleeve carrying nozzle (
B
) with the aid of a standard
27 mm wrench. After removing the sleeve, use a standard
16 mm wrench to remove the cone holding clamps (
P
) and
extract the clamps (
M
). When replacing the nozzle (
A
), use a
standard 12 mm wrench and place the removed nozzle in the
housing provided on the bottom of the riveting tool so as to
avoid losing it.
f4
f3
f5